background image

 
 

 

 

 
 
 

 

 

               Rev.:1  

 

 

Page 

11

 of 

15

 

 

 

 

eLAN-IR-003 

In case you wish to set static IP address, please mark relevant line and fill in the details:  

IP Address 

– enter the new IP address of the eLAN-IR-003 (in dotted decimal format). In case 

you set the static IP address, you have to find it by using the application (see detailed manual 
for applications). 

Subnet Mask 

 –

 

a code determining the size of the network, normally used for subnet mask is 

the value 255.255.255.0.  

Default gateway 

 – enter the default gateway according to the settings of your network (this is 

usually the IP address of your router).

 

 

Note:

 

If you change the IP address, to log into the eLAN-RF-003 you must use the new IP address. If 

the  new  IP  address  that  you  entered  is  not  in  the  same  subnetwork,  the  connection  will  not  work  if 
settings are not changed in the connected device (PC, iMM Client) to the same subnetwork

 

 

 
 

 

 

The button 

Update firmware

 is used to update the firmware in your eLAN-IR-003.  

You can download the latest FW version from the Website: 
http://www.elkoep.cz/ke-stazeni/software/   
If you are experiencing no difficulties with the  eLAN-IR, it is not necessary to download the latest 
firmware version.  

 
 

 

Panel 

Rooms

 - create a room.  

Button (

+

) - add a new room: 

 

 

 

1. 

ID

 *of the room "optional data", if you do not enter it - a number is automatically generated. 

Here you can only use the characters [0-9A-Za-z_-]. 

2. 

Label

 gives an arbitrary name to the room (you can use diacritical marks, gaps and others...) 

3. 

Type

 – here you select the type of room or type of icon that you will then display after entering 

the floorplan on the desktop. 

4. 

Floorplan

 – here select the floorplan (image) that you added before in the tab 

Floorplans

Button (

) - remove the selected room. 

Button (

X

) - remove all created rooms.  

 
Control of the device via Rooms 

Rooms can be used to send IR codes (commands) directly from the web interface eLAN-IR-003.   
By  clicking  on  the  required  icon,  open  in  the  Configuration  Panel  the  option  IR  codes  assigned  to 
control functions of the given device.  
By  double-clicking  on  the  required  IR  code,  you  will  run  the  assigned  function  (a  functioning  IR 
transmitter must be connected).  
Flashing of STATUS LED of the given output confirms sending of the IR code. 

Summary of Contents for eLAN-IR-003

Page 1: ...Rev 1 Page 1 of 15 eLAN IR 003 ...

Page 2: ...eLAN IR 003 3 3 Technical parameters 4 4 Hardware installation 5 4 1 Description of eLAN IR 003 5 4 2 Requirements for installation 6 4 3 Connecting the eLAN IR 003 7 5 Configuring the eLAN IR 003 8 5 1 Configuration panel 9 5 2 Description of functions 10 6 Troubleshooting 15 ...

Page 3: ... multimedia from the iHC app or when an iMM shows an IR signal it can control the TV an amplifier and smart phone or a tablet and gyroscopic mouse and it serves as the sole driver of the entire system An independent facility or an IR terror drivers which unites all drivers under one and replacing it with a smart phone without having to use iNELS complex system eLAN IR 003 converter Ethernet comman...

Page 4: ...erface 10 100 Mbps RJ45 POWER SUPPLY Voltage supply rated current 10 27 V DC 200 mA safe low voltage Connection Jack connector O 2 1 mm Voltage supply indication Green LED OTHER DATA Other possibilities of wiring USB B connector Indication Yellow USB LED status Reset button settings to their default values Power supply 230 V AC 12 V DC supplied with the data logger OPERATING CONDITIONS Operating t...

Page 5: ...t the USB port LED indicator of Ethernet yellow operation status indicator green communication indicator Input for connector Ethernet RJ45 for connection to local network LAN or PC RESET button RESTART press 1s performs device restart current settings do not change RESET press 10s returns device to factory settings i e reading IP address from DHCP user name and password set to admin user elkoep de...

Page 6: ... IR 003 may not be placed in a spot where it would be exposed to moisture or excessive temperatures The connected IR transmitter must be in directionally and visibly aligned with the receiver and at an adequate distance from the controlled device For flawless IR communication the transmitter cannot become contaminated The emission characteristics of the transmitter are displayed by a symbol in the...

Page 7: ... eLAN IR 003 an IP address Connect to output IR1 IR2 IR3 IR transmitter included in package Place the IR transmitter at the required distance from the controlled device Turn the IR transmitter to the position based on the emission characteristics see point 4 2 Test the function of the IR connection Affix the IR transmitter at the required spot using tape on the IR transmitter Example of typical co...

Page 8: ...nits appear that are located in your home network to which you are currently connected by phone as well as their IP addresses Run the web browser In the Internet browser in the Address panel fill in the IP address of your eLAN IR 003 After confirming the entered IP address the web server s login page will come up A sign in window will appear on the start screen Factory settings for signing in as a...

Page 9: ...Rev 1 Page 9 of 15 eLAN IR 003 5 1 Configuration panel ...

Page 10: ...b interface eLAN IR 003 By pressing the button Save settings you can save the current settings of your eLAN IR 003 including network settings By pressing the button Load settings you can restore your stored settings which you have already stored in your PC the file has the extension bin The button Settings is to configure network settings that you can change any time based on your network ...

Page 11: ...Website http www elkoep cz ke stazeni software If you are experiencing no difficulties with the eLAN IR it is not necessary to download the latest firmware version Panel Rooms create a room Button add a new room 1 ID of the room optional data if you do not enter it a number is automatically generated Here you can only use the characters 0 9A Za z_ 2 Label gives an arbitrary name to the room you ca...

Page 12: ...or the needs of R D The panel Room Types do not adjust or delete anything only for the needs of R D Panel Action displays options for controlling the device indicated on the floor plan Panel Scenes create a scene ATTENTION You can only create scenes after adding a device see Devices and loading IR codes for individual device functions see IR codes Button add a new scene 1 ID name of room not requi...

Page 13: ...eate IR device will appear where you will enter the device name Label and type of device Type By clicking on the button the window Create Action will appear where you select commands 1 Name name of function 2 IR LED selection of IR transmitter which the device is supposed to control 3 IR codes selection of loaded IR code from the list Available Confirm by pressing Create Button delete selected com...

Page 14: ...pressing this activates the IR signal receiver on the eLAN IR 003 Then you can load codes from the controller Import if you have IR codes stored in your PC you can load them directly You can verify receipt of the IR codes directly in the Configuration panel where you will see displayed in the Status row Status Recording IR code Button deletes the selected code Button X deletes all codes ...

Page 15: ...for 1 s or by disconnecting and reconnecting the power supply The device does not react to sent IR commands Recheck connection to the power source and to the Ethernet network connection of the IR transmitter to the applicable IR transmitter output flashing LED STATUS of the applicable IR transmitter output when sending the IR signal If the LED STATUS is not flashing the cause may be an incorrectly...