The maintenance for the SIPP Node 400 should be done on a regular basis.
We recommend that the condition of the unit and pit is controlled at each inspection of the station and
documented according to appendix V.
Changing filter and replacing the measuring cell can be carried out by any service personnel that are
familiar with this manual.
Important!
After changing filter or replacing the measuring cell these actions MUST be registered in SIPP Warehouse
!
Registration of filter replacement and calibration of the measuring cell as well as manual
start and reset of the device can be done by:
1. Scan unit QR code, enter the access code and then follow the instructions.
2. Contact support via SMS, telephone or email
All other types of service work must be carried out by trained service technicians.
Only
spare parts from IA may be used for the service work.
Measuring cell
680001
Allen screwdriver 4 mm
After 250 m
3
of discharged water
or 4 years after commissioning.
Filter unit
665201
After 50 m
3
of discharged water or
2 years
Industriarmatur cannot be held responsible for any damages on the
unit due to incorrect use or if no maintenance has been carried out
on the unit. Before performing service on the unit, the voltage cable
must be unplugged to prevent the user from the risk of getting in
contact with live conductors. Only authorised personnel are allowed
to open the unit’s electronic device.