Rev. 8: 29-04-2021
18
How to access to the Raspberry PLC
Raspberry PLC access
To facilitate the connection to the Raspberry PLC, our company has set a default IP for it. For
the first time of use, an Ethernet connection between the Raspberry PLC and a PC will be
necessary. The Raspberry is given with the local IP address
10.10.10.20/24*
, the default user is
pi
and the password is
raspberry
. For connecting to it, you must change your local address for
being in the same local network as the Raspberry. After the first connection you can add users
or change each user’s password anytime.
In order to know if the Raspberry is connected and
the Ethernet connection is going on, a
ping
command can be run on the terminal (for windows
users enter
cnm
in the windows searching tab to open it):
*Note:
To use this local IP address you must connect the Ethernet cable to the Ethernet port
located in the right side of the PLC. Do not use the upper side Ethernet port for this purpose.
The steps to follow for both Linux and Windows are explained below:
5.1.1
Linux
In order to access the Raspberry PLC, Linux users have to enter by SSH protocol, which should
have been installed before by the user. As has been said, the Raspberry is given with a local IP
address by default for making an easier path for the customer. So, first of all we have to check
if our local
Ethernet Network
is set with the same local IP address as our raspberrian device. In
case that you do not know how to set it, check the section 6 of the guide. As have been
mentioned before, you can use the
ping
command with the
address 10.10.10.20
as option:
Summary of Contents for Raspberry PLC 19R+
Page 1: ...RASPBERRY PLC FAMILY RASPBERRY PLC FAMILY...
Page 2: ...Rev 8 29 04 2021 1...
Page 3: ...Rev 8 29 04 2021 2 RASPBERRY PLC FAMILY Quick User Guide Revised February 2021...
Page 9: ...Rev 8 29 04 2021 8 General Description RASPBERRY PLC FAMILY Product Reference Table...
Page 10: ...Rev 8 29 04 2021 9 Zones Table Measures Table...
Page 27: ...Rev 8 29 04 2021 26 Raspberry PLC Family Pinout I Os Table...
Page 29: ...Rev 8 29 04 2021 28 Upper Side POWER INDICATOR RTC BATTERY CAN BUS ETHERNET2 CONNECTOR...
Page 35: ...Rev 8 29 04 2021 34 Equivalence Table Pin Out 11 1 1 Analog Digital Devices Analog I Os...
Page 36: ...Rev 8 29 04 2021 35 11 1 2 Digital I Os 11 1 3 Relay Devices Analog I Os...
Page 37: ...Rev 8 29 04 2021 36 11 1 4 Digital I Os 11 1 5 Relay...
Page 53: ...Rev 8 29 04 2021 52 Mail industrialshields industrialshields com...