Ref. IS.MDUINO.XXX
1.3
A Zone Features
Shield
A Zone
Communication
Shield
(1x) Ethernet
(1x) USB
(1x) I2C
(3x) TTL
(1x) RS-232
(1x) HALF/FULL Duplex RS-485
(1x) SPI external Port
(1x) RTC
(1x) uSD Socket
This is the list of our products depending on the combination of the shields. As it is
already said above the A Zone is totally common for all the M-Duino Family.
The nomenclature of the M-Duino Family products consists on placing the name of the
Shield/s after the total number of I/Os of the product.
For example M-Dui is a PLC with the 3 extra Zones (B, C, D), which are
Analog, Relay, Relay respectively. It has 53 I/Os.
M-Duino
B Zone
C Zone
D Zone
M-Dui
A
R
R
* There are 2 different exceptions. M-D/M-D should be called with this nomenclature M-
Du/M-Dui, as everything is Relay it is omitted. Also for the M-/42+/58+ as
they are all Analog they are not represented with this nomenclature. With the nomenclature represented in
the User Guide they would be: M-D/M-Du/M-Dui
M-Duino
B Zone
C Zone
D Zone
Analog Relay Analog
Relay
Analog Relay
M-Duino 19R+
X
M-Duino 21+
X
M-Duino 38R+
X
X
M-Duino 38AR+
X
X
M-Duino 42+
X
X
M-Duino 50RRA+
X
X
X
M-Duino 53ARR+
X
X
X
M-Duino 53ARA+
X
X
X
M-Duino 57AAR+
X
X
X
M-Duino 57R+
X
X
X
M-Duino 58+
X
X
X
Summary of Contents for M-DUINO PLUS series
Page 1: ...Ref IS MDUINO XXX M DUINO PLUS FAMILY M Duino PLUS Family User Guide ...
Page 2: ...Ref IS MDUINO XXX ...
Page 3: ...Ref IS MDUINO XXX Ethernet PLC User Guide Revised March 2018 ...
Page 39: ...Ref IS MDUINO XXX Analog Out Turn On Analog Out Turn Off Analog Digital input Turn on ...
Page 40: ...Ref IS MDUINO XXX Typical Connections ...
Page 41: ...Ref IS MDUINO XXX ...
Page 42: ...Ref IS MDUINO XXX ...
Page 43: ...Ref IS MDUINO XXX ...
Page 45: ...Ref IS MDUINO XXX Mechanical Characteristics Dimension M duino Family DIN Rail mounting ...