23
Table 2.6 Sensor specifications
Gas type (abbreviation)
Part number
Hydrogen Sulfide (H
2
S)
Hydrogen Sulfide (H
2
S)
17155304-2
17155306-2
Properties
Category
Toxic
Toxic
Technology
Electrochemical
Electrochemical
DualSense™ capable
No
No
Installation location
Ventis Pro4
1 or 2
3 or 4
Ventis Pro5
1 or 2
3 or 4
Operating conditions
Temperature range
a
-40 to +50 °C (-40 to +122°F)
-40 to +50 °C (-40 to +122°F)
RH range
a
15-95%
15-95%
Performance
Sensitivity
Measurement range
0−500 ppm
0−500 ppm
Measurement resolution
0.1 ppm
0.1 ppm
Accuracy
b
Calibration gas and
concentration
25 ppm
25 ppm
Accuracy at time and
temperature of calibration
± 5% (0-400 ppm)
± 7% (401-500 ppm)
± 7%
Accuracy over sensor’s
full temperature range
± 15%
± 15%
Response Time
T50
10 s
10 s
T90
25 s
25 s