26
MECHANICAL INSTALLATION
1. Mechanical installation must be completed prior to assembly of hood/skirt and electrical wiring.
2.
With the proper lift, raise the Air Cleaner off the floor high enough to attach the column support
brackets. Brace unit to prevent fall.
3.
Using the provided 3/8” x 1” bolts, flat washers & lock nuts, securely fasten the columns support
brackets to the Air Cleaner frame. Make sure to align the bracket so that the inside corner fits
snug against the air cleaner frame. Use Minimum of 6 bolts per bracket.
4. Safely place air cleaner in the desired location and elevate to install support columns. Brace the
unit to avoid fall.
5. Carefully slide a 4 x 4 column into each support bracket and tighten all for pre -installed 1/2 x 1
bolts. Make sure column is pushed firmly into bracket, fitting tight against the end cap. NOTE-
columns may need to be cut down to achieve proper overall height.
6. With unit suspended, attach 2 x2 angle braces on each end, using the 3/8 x 5 and 3/8 x 1 bolts,
flat washers and lock nuts provided.
7. Carefully lower unit to desired location
8.
Anchor base plates to floor using (16) 3/8 x 6 anchor bolts, not provided.
9. Refer to Appendix A for hood/skirt installation
10.
Install lighting and electrical control, by qualified electrician according to NEC, state and local
code