Installation:
The gas supply pressure for this stove are:
Under these conditions, the operation will be the correct one.
Ecuador
Other Countries
27.5 mbar = 2.75 kPa ( For liquefied petroleum gas LPG use )
28 mbar = 2.8 kPa ( For liquefied petroleum gas LPG use)
20 mbar = 2.0 kPa ( For natural gas GN use)
GENERAL CONDITIONS
- The installation must be carried out by qualified personnel.
- Read all the technical instructions before installing.
- Before installation, be sure local distribution conditions (Nature and pressure of the
gas) and gas appliance adjustment are compatible.
- Setting conditions for the gas appliance are located on the back identification label
or identification plate:
• Category I 3, stoves that work only on LPG.
• Category II 2-3, stoves that can run on LPG or NG.
- This gas appliance is not designed to be connected to a device evacuation
combustion products. Its installation and connection should be performed in
accordance with the installation standards. Pay special attention to the provisions
concerning to ventilation (Reference to Chile: Gas Installations Act No. 66).
- The area where you will install the appliance should include ventilation conditions, as
required in the last upgrade Standard NTC 3631 . (Reference for Colombia).
- This device is set to be installed from 0 to 4000 meters above sea level; therefore you
do not need to modify it to different local atmospheric pressure conditions and room
temperature.
- When installing the stove, it is necessary to comply with the provisions according to
NTC NTC 2505 and 3632 Standards (Reference for Colombia)
- Burners output ratings data are founded on the general characteristics sheet
attached to this manual.
- In case of adjustments, repair or maintenance of the stove, see the diagram which
indicates the general description of the parts and components that must be
removed.
- If you need to change the type of gas that will operate the appliance, follow the
setting instructions given in the section "Converting to different gases." (It applies only
to stove models in the Category II2-3).
- The manufacturer is not responsible for faulty installation that may cause accidents.
INSTALLER MANUAL
Installation and setup
Instructions Manual
PAG 4
max 2 cm.
(1”)
If your appliance has a top closure, comply
with the maximum size shown in this picture
according to working adjacent surfaces.
When you install your appliance; be sure
not to block the furnance gases exit from
the chimney or gills.
If the stove is going to be installed next to
a wooden wall; the appliance must be
placed between a fire-resistant material
and the wall. With dimensions of width
and height which exceed in 4 cm. (≈1.6’’)
to the stove.
e
not t
o block the chimne
y
f
g
INSTALLER MANUAL
Installation and setup
PAG 3
Instructions Manual
To prevent lodging, the
appliance should be
anchored to the wall through
the fixing system located in
the back.
DRILLING ON
WALL
DRILL 5mm (3/16”)
FISCHER PLUG
EYEBOLT
CHAIN
DIMENSIONS FOR DRILLING THE WALL
1)
770 mm (≈30.3”) STOVES 32”
2)
840 mm (≈33”)
570 mm ( ≈22.5”) STOVES 24”
487 mm (≈19.2”) STOVES 20”
NOTE:
If your stove has a fixed system or take within fixed accessories, follow the instructions
below to avoid accidents with rollovers in your appliances.
Follow the minimum or maximum
dimensions shown in this image.
d
min. 60 cm.
mín. 10 cm.
( ≈4’’ )
mín. 15 cm.
( ≈6’’ )
( ≈1’’ )
( ≈1’’ )
mín. 2 cm.
mín. 2 cm.
mín. 65cm.
( ≈24’’ )
( ≈26’’ )
max. 33 cm.
( ≈13’’ )