Web application
PROmesh P9+
– User Manual
42
Figure 19: Time server
Automatically (SNTP)
SNTP Server: Store the IP address of the time server. It is possible to store a second time server
as redundancy.
Update interval: You can determine the cycle in which the device time is synchronised with the
time server here.
Time zone: Then select your valid time zone
Manual
This setting lets you manually enter the current date and time by clicking the calendar icon.
Furthermore, you can select your valid time zone under “Time zone”.
SNMP
The Simple Network Management Protocol (SNMP) controls communication between the monitored
devices and the monitoring station. It enables the reading and writing of system variables.
Current SNMP accesses
The overview table shows you the currently defined community strings and access permissions.
Active: Indicates which community strings are currently enable and which are not.
Community string: The accesses are defined by unique names that you can change.