![Indu-Sol EmCheck ISMZ I User Manual Download Page 17](http://html1.mh-extra.com/html/indu-sol/emcheck-ismz-i/emcheck-ismz-i_user-manual_2054026017.webp)
Control software EmCheck® View
Intelligent current clamp meter ISMZ I
– User Manual
17
Data evaluation with E
M
Check
®
View
Import of up to four EMC-
files is possible by clicking the button “Add measurement data” in the top left
corner.
Figure 7: E
M
Check
®
View data evaluation
You can change the displayed time frame for the display by drawing a frame with the mouse over the
current course.
Using the arrow buttons next to the displayed time range, you can switch into previously set time ranges.
All time ranges created till now are expanded by clicking on the time range.
By clicking on the button “Sp”, you can switch from “Current course” to the “frequency specter” of the shown
graph.
Figure 8: E
M
Check
®
View data evaluation, Current course and frequency specter
Current course,
Zoom with mouse
selection
Zoom Y-axis
(current)
Zoom X-axis
(time)
Current course /
frequency specter