28
7.Appendix
7.Appendix1. Use for overheating protector
Overheating protector is used to prevent safety accident caused by water temperature inside the
tank too high in case that the heat pump controller is out of control. When the temperature inside the
tank reaches the action value of the protector, the power supply will be cut off. It has to be reset
manually so that the unit returns to normal. The operation in detail is as following:
Press the red button to reset
Protection cover of the protector
Be careful of electric shock when you press red button.
Warning
6.2 Trouble Shooting
For any malfunctions, please refer to the table below :
P01
Top tank water
temp. Failure
P02
Coil temp. Failure
P04
P05
P07
E01
E02
E03
E04
E07
E08
E09
Ambient
temp. Failure
Refrigerant absorb
temp. Failure
High pressure protection
Low pressure protection
Water flow failure
Electric-heater
overheat protection
Anti-freeze protection
Communication failure
Winter frost protection
P09
Anti-freeze temp. Failure
Bottom water
temp. Failure
Malfunction
Display
Canse
Solution
The water b
temp. Sensor
is open or short circuit
ottom
The water top tank temp. sensor
is open or short circuit
The ambient temp. sensor
is open or short circuit
The pipe temp. sensor is
open or short circuit
The evaporator temp. Sensor
is open or short circuit
The exhaust pressure is high ,
high pressure switch action
The suction pressure is low,
Low pressure switch action
No water or litter water
in water system
Wired remote control with master
signal failure
Ambient temperature is too low
Water flow volume not enough,Water
system pressure difference is small
Water flow volume not enough,Water
system pressure difference is small
Check or change the water
bottom temp. Sensor
Check or change the water
top tank temp. Sensor
Check or change the
ambient temp.
S
ensor
Check or change the
pipe temp.
S
ensor
Check or change the
evaporator temp. Sensor
Check high pressure switch
and cooling return circuit
Check low pressure switch and
cooling return circuit
Check the flow volume ,water
pump is failure or not
Check the flow volume,water
system is jammed or not
Check the flow volume,water
system is jammed or not
The a
Sensor
is open or short circuit
nti-freeze temp.
Check or change the
a
Sensor
nti-freeze temp.
P034
Solar temp. Failure
Check the connection line between
the wired remote control and
motherboard
The solar
Sensor
is open or short circuit
temp.
Check or change the
solar
Sensor
temp.