4.Installation
4.2 Choose the Suitable Unit
Notice: The choice is just for reference, please choose the unit according to native
environment and custom.
4.3 D
eposited and Transportation
As a rule, the unit is to be stored and/or transported in its shipping container in upright
position and without water charge. For a transport over short distance, and provided due
care is exercised, an inclination angle of up to 30 degree is permitted. Both during
transport and storage, ambient temperatures of 0
to +43
are permissible.
4.4.1 Transport using a forklift
When transported by a fork lift, the unit must remain mounted on the pallet. The lifting
rate should be kept to a minimum. Due to its top-heaviness, the unit must be secured
against tipping over. To prevent any damage, the unit must be placed on a level surface!
4.4.2 Manual transport
For the manual transport, the wooden pallet can be used for bottom part. Using ropes or
carrying straps, a second or third handling configuration is possible. With this type of
handling, care must be taken that the max. Permissible inclination angle of 60 degree is
not exceeded. If transport in an inclined position cannot be avoided, the unit should be
taken into operation one hour after it has been moved into final position.
CAUTION
High center of gravity, low overturning moment!
60