16.
Example: Distance between guide pulley and belt clamping
1
Guide pulley at drive
2
Belt clamping
Replace Z8 gantry type receiver belt. The value of 400mm listed in the table
refers to the distance between the center of the guide pulley on drive 1 and the
center of the belt clamping of this unit 2 (see example: distance between guide
pulley and belt clamping). This value or distance is necessary to accurately
adjust the belt tension.
17. Measure belt tension (frequency meter) and adjust belt.
18. Replace the belt of the work area door drive.
19.
Example: Auto_Arbeitsraumtuer_1_R200
X
Center between the drive pulley and the deflection pulley
1
Belt adjustment
Measure belt tension and adjust belt. The measuring point to check the belt
frequency is located in the middle (X) between the belt pulley and the
deflection pulley. A spring scale is used to adjust the belt. At position X, a
Maintenance Summary - 4.000 Operating hours
97
Maintenance Instructions
R200
LR1702.10181 - 05.06.2019