Service Manual
SIDE-BYSIDE
Edition
2008.09.02
POWER MODULE Parameters
DEFROST HEATING ELEMENTS
• Compressor ON time since the last defrost cycle.
8 hours, but the start time will reduce dependant on
door opening times.
• The appliance is plugged in and switched on.
• Total time since the last defrost cycle.
50 hours, but the start time will reduce dependant on
door opening times.
• Maximum time defrost heater is ON.
Approximately 20 minutes
Defrost end temperature (freezer defrost cut-out).
+7°C ± 3°C
Defrost Heating Elements -
The parameters utilised to start the
defrost cycle are as follows:
FREEZER FAN OPERATION
Freezer Fan Operation -
The freezer fan is managed by the
power module and is switched on/off
after a preset time interval that is
parameterised in the memory after a
compressor start/stop.
After the defrost cycle the fan starts after a timed interval
following a compressor start, also this interval is
parameterised in the memory;
Compressor 7 minutes PLUS 3 minutes for the Fan
= 10 minutes