19
Language
English
Service Manual
SIDE-BYSIDE
Edition
2008.09.02
AUTO TEST
This helps with a quick check of the loads and sensors (thermistors), which otherwise are diffi cult to activate.
NOTE: - Before using the AUTO-TEST it is advisable to check the correct operation of the temperature 7-
segment LEDs (both fridge and freezer display), which are used for signalling possible malfunctions. Ensure
the Super Freeze or Holiday modes have not been selected before starting the AUTO-TEST.
SIDE X SIDE
NO-FROST
MODELS
MSZ801DF
(cc48862)
MSZ802DF
(cc48863)
MSZ803DF
(cc46196)
TO ACTIVATE
TO
DEACTIVATE
Sequence of check codes is indicated in
the Freezer display (Sequence Duration)
STEP 1: If the
appliance has
been connected
to the mains
power for more
than 15
minutes, discon-
nect it and
wait 40 seconds
before
reconnecting it
back to the mains
supply.
STEP 2: Wait until
the display
completes its
set-up and returns
to normal
operation.
STEP 3: Open
the freezer door.
STEP 4: Press
the freezer light
switch 3 times
within 10
seconds.
STEP 5: The test
is activated when
sequence ‘07’
appears in the
freezer
temperature
display.
Manually:
Switching OFF
the power supply
to the appliance.
Sequence Code 07: (3 seconds)
Evaporator Defrost Heater,
Sequence Code 06: (3 seconds)
Fridge Sensor,
Sequence Code 05: (3 seconds)
Freezer Sensor,
Sequence Code 04: (3 seconds)
Evaporator Fan,
Sequence Code 02 to 00 fl ashing
alternatively: (2.5 minutes)
Baffl e/damper triac Q3,
Sequence Code 09: (3 seconds)
Water Valve (Ice Maker),
Sequence Code 12 to 00 fl ashing
alternatively: (60 seconds)
Ice Maker,
Sequence Code 01 to 00 fl ashing
alternatively:
Water Valve (Washer Dispenser),
NOTE: Confi rm by pressing ice water
dispenser pedal,
Sequence Code 00:
END.
NOTE: Auto Test needs to be deactivated
manually. See previous column.