Indel motion boards
Technical details
Single-ended incremental encoders
Additional level adjustment is required if single-ended incremental encoders are being used. A
connection must be made to the encoder interface at jacks X3A and X4A and to the absolute feedback
interface at jacks X3B and X4B. Fig. 7 und Fig. 8 give an example for the absolute feedback interface.
However, we generally recommend that you use incremental encoders with a RS422 interface
as per the current industry standard.
Rev 1.31; 04/11/2013
Page 25/54
Fig. 7: Connection example for 24V single-ended incremental
encoder
Fig. 8: Connection example for 5V single-ended incremental encoder