background image

5

- Do not vacuum substances which can cause cancer or other 

diseases (i.e. Lead, Silica, Arsenic, Chromium, Asbestos etc.);

- Do not vacuum sanding dust from surfaces treated with paints 

that have not completed the catalyst cycle;

- Do not vacuum sparks or white hot shavings;

- Immediately disconnect the vacuum cleaner from the electrical 

mains if dust is ejected from air outlet;

- Connect to a properly grounded outlet only. See grounding in-

structions;

- VERSION “E”: immediately disconnect the machine from the 

power supply if you notice the presence of foam or liquid leaking 

during the vacuuming of liquid;

- VERSION “E”: Do not use to pick up flammable or combustible 

liquids, such as gasoline, or use in areas where they may be 

present;

- VERSION “E”: do not vacuum aggressive liquids or substances 

(i.e. acids, bases, solvents, etc.);

- FOR WET/DRY UNITS: WARNING - To reduce the risk of elec-

tric shock - use indoors only; 

- FOR DRY ONLY UNITS: WARNING - To reduce the risk of elec-

tric shock - do not use outdoors or on wet surfaces; 

SAVE THESE INSTRUCTIONS
INTENDED USE

- This appliance is suitable for household, commercial or both - 

This appliance is suitable for household, commercial or both 

use, in accordance with CSA C22.2 No 243-15 and UL 1017;

- This appliance is suitable for the aspiration of non-noxious 

dusts, dirt, sand, shavings, liquids (Version “E” only), etc.;

- The anterior panel power outlet and pneumatic quick coupling 

are intended for the specific use indicated in the present in-

struction manual;

- VERSION “E”: this appliance is suitable for vacuuming liquids;

 WARNING

 – Refer to all regulations applicable to the sub-

stances and pollutant collected.

TECHNICAL SPECIFICATIONS

OPERATING VOLTAGE AND FREQUENCY 120 Vac - 50/60 Hz
Vacuum Cleaner POWER

1030 W

POWER AT SOCKET (MAX)

680 W

TOTAL POWER (MAX)

1710 W

AIR CAPACITY

(According to IEC 60335-2-69)

165 m3/h (97,12 CFM)

VACUUM LEVEL

215 hPa (215 mbar)

WEIGHT

13,5 kg (29,76 lbs) (S145)

DIMENSIONS

cm 47 x 45 x 63,5 

(Inches 

18,5 x 17,72 x 25)

 

CLASS OF PROTECTION

IP X 4

NOISE LEVEL (According to IEC60704-3) 70 dB(A) - 73 dB(A)  

VERSION “E”

FILTERS SURFACES

2 x 0,50 m

2

 (2 x 775 in

2

)

CAPACITY OF FILTER BAG

kg 5 (lbs 11,02) max

CONTAINER CAPACITY

45 l (11,89 gal.)

POWER CONTROL SWITCH

MAN - O - AUT

VERSION “P”

INLET AIR PRESSURE

6 bar (87,02 PSI)

MAX COMPRESSED AIR FLOW

1450 l/min (383 gal./min)

INLET FITTING

3/8” G female

PARTS OF THE TOOL

1 - Vacuum head

2 - Tool tray

3 - Handle

4 - Identification plate

5 - Compressed air inlet (VERSION “P”)

6 - Air coupling filter (VERSION “P”)

7 - Power cord

8 - Cooling air inlet

9 - Cooling air outlet

10 - Operating air outlet

11 - Head lockers

12 - Man-0-Aut switch with speed control

13 - Motor ON indicator

14 - Liquid level indicator (VERSION “E”)

15 - Service indicator

16 - Anterior panel outlet

17 - Quick coupling for pneumatic tool (VERSION “P”)

18 - Pneumatic tool connection

19 - Vacuum hose

20 - Pneumatic tool hose (optional)

21 - Filter frame

22 - Filter frames lockers

23 - Filters

24 - Liquid level sensor (VERSION “E”)

25 - Dust bin

26 - Accessories compartment (VERSION 45 l)

27 - Antistatic connection

28 - Hose nozzle

29 - Y way

30 - Filter bag

31 - Castor wheels with lock

START-UP

Power supply

-  Turn the main switch (12) to “O” (off) before connecting this 

appliance to the supply mains;

-  Supply mains voltage and frequency must match the identifica-

tion plate;

- Connect to power socket outlets provided with earth conductor 

and adequate protections.

Grounding Instructions

This appliance must be grounded. If it should malfunction or 

breakdown, grounding provides a path of least resistance for 

electric current to reduce the risk of electric shock. This appliance 

is equipped with a cord having an equipment-grounding conduc-

tor and grounding plug. The plug must be inserted into an appro-

priate outlet that is properly installed and grounded in accordance 

with all local codes and ordinances.

This appliance is rated 15 A on a circuit having a nominal rating of 

120 V. It is factory-equipped with a specific electric cord and plug 

to permit connection to a proper electric circuit. 

Make sure that the appliance is connected to an outlet having the 

same configuration as the plug. 

No adaptor should be used with this appliance.

Summary of Contents for LPE 45L US

Page 1: ...rit veillez bien LIRE et COMPRENDRE le pr sent manuel d instructions avant d utiliser la machine ADVERTENCIA Por su propia seguridad lea el manual de instrucciones antes de utilizar el parato SAVE THE...

Page 2: ...29 25 1 3 4 5 2 9 11 10 4 5 6 45 lt 3 1 16 7 17 24 15 14 13 12 8 23 22 21 30 28 31 25 26 45 lt 45 lt 2...

Page 3: ...3 0 0 7 0 0 9 10 11 12 13 14 15 16 17 19 20 18 20 18 6 27 6 7 8...

Page 4: ...e operated by kids or mental sensorial defec tive people Do not allow to be used as a toy Close attention is necessary when used near children Use only as described in this manual Use only manufacture...

Page 5: ...ASS OF PROTECTION IP X 4 NOISE LEVEL According to IEC60704 3 70 dB A 73 dB A VERSION E FILTERS SURFACES 2 x 0 50 m2 2 x 775 in2 CAPACITY OF FILTER BAG kg 5 lbs 11 02 max CONTAINER CAPACITY 45 l 11 89...

Page 6: ...in doubt as to whether the outlet is properly grounded Do not mod ify the plug provided with the appliance if it will not fit the outlet have a proper outlet installed by a qualified electrician Compr...

Page 7: ...cement Wear adequate filter mask Detach the vacuum head pulling out the side hooks 11 pic 7 8 Turn the vacuum head upside down pic 12 Remove the filter frame 21 turning the hooks 22 pic 13 Remove the...

Page 8: ...teignez toutes les commandes avant de d brancher Faites attention en cas de nettoyage sur les escaliers Ne tirez pas ne transportez par l appareil en utilisant son c ble N utilisez pas le c ble comme...

Page 9: ...SSE DE PROTECTION IP X 4 NIVEAU BRUIT Selon IEC60704 3 70 dB A 73 dB A VERSION E SURFACES FILTRES 2 x 0 50 m2 2 x 775 in2 CAPACIT DU SAC A FILTRE kg 5 lbs 11 02 max CAPACIT R CIPIENT 45 l 11 89 gal IN...

Page 10: ...ersonne de service si vous avez des doutes quant savoir si la prise de courant est correctement mise la terre Ne modifiez pas la fiche fournie avec l appareil si elle ne correspond pas la prise faites...

Page 11: ...n dant le remplacement du sac filtre Portez un masque filtre ad quat D tachez la t te d aspiration en tirant les crochets lat raux 11 photos 7 et 8 Retournez la t te d aspiration photo 12 Retirez le c...

Page 12: ...un juguete Preste mucha atenci n cuando se utilice cerca de ni os Util cela solo como se describe en este manual Utilice nica mente los accesorios recomendados por el fabricante Antes de su uso los us...

Page 13: ...LA HERRAMIENTA 1 Cabezal de aspiraci n 2 Bandeja de herramientas 3 Asa 4 Placa de identificaci n 5 Entrada de aire comprimido VERSI N P 6 Filtro de acoplamiento de aire VERSI N P 7 Cable de alimentac...

Page 14: ...que est totalmente unida No utilice un cable de extensi n que presente una conexi n floja Una conexi n floja puede provocar sobrecalentamiento o un in cendio y aumenta el riesgo de quemaduras Para red...

Page 15: ...adecuada Separe el cabezal de la aspiradora tirando de los ganchos lat erales 11 fig 7 8 Voltee al rev s el cabezal de la aspiradora fig 12 Quite el marco del filtro 21 girando los ganchos 22 fig 13...

Page 16: ...d 9 2483 07 2015 Cod 9 2586 IND USA 06 2019 INDASA Industria de Abrasivos S A P O Box 3005 I 3801 101 Aveiro Tel 351 234 303 600 Fax 351 234 303 605 E mail indasa indasa pt Web www indasa abrasives co...

Reviews: