Fault Finding
Please check before contacting us about any issues
Black scorch marks on the
incinerator body
Thermocouple failure
Steam from the incinerator
during the curing process
Small cracks within the
refractory concrete
Large cracks
Burner flame appears to turn
up the chimney
Flames from the chimney
"Booming" noise from the
incinerator during operation
Smooth appears from the
joint of the incinerator body
and top
Control Panel displays
"0000"
Grey/white smoke
Black smoke
Burner issues
Leakage from damaged fire
rope or misaligned door
Excessive temperature or
corrosion from waste gases or
fluids
Water within the refractory
concrete
Expansion/contraction whilst
heating/cooling
Wear & tear
Too much draw from chimney
Too much flammable waste in
the main chamber
Main chamber overfilled or air
setting too high
Mastic sealing joint is
damaged
Thermocouple failure resulting
from loose connection
Temperature is too low
Insufficient oxygen in main
chamber
Replace fire rope or realign door
Replace thermocouple
This is completely normal
This is completely normal
Repair with high temperature cement or
mastic
If chimney has been extended, this is too high
Reduce waste batch size
Reduce waste batch size or lower air setting
Reseal the joint with high temperature mastic
Check wiring or replace thermocouple
Increase temperature or ensure unit is
pre-heated
Reduce waste batch size. It is sometimes
better to burn smaller batches more regularly
Please refer to fault finding section in
enclosed burner manual
PROBLEM
CAUSE
SOLUTION