Technical Characteristics

All characteristics are applied for T = 25°C, Supply via USB. Typical values unless otherwise stated.

Electrical Characteristics

Power Supply (VDD)

4.5 - 5.25V

Current Consumption (typ.)

Sleep mode:  4µA (RTC on)
Infrared receive:  5mA
HCI active:  10mA
Transmit mode:  30mA

Data Memory

8 MBit Flash

RF Characteristics

Frequency range

863 MHz to 870 MHz

RF output power

+13 dBm ERP with supplied antenna

Modulation

LoRa  Spread-Spectrum

®

(G)FSK

Antenna

Via MMCX connector

LoRa  Protocol Characteristics

®

LoRaWAN

®

Certified and compliant to V.1.0.2

Activation type

ABP (activation by personalization)
OTAA (over the air activation)

Frequencies

Standard LoRaWAN frequencies

Additional frequencies depend on LoRaWAN  network server

®

Supported Energy Meter Protocols/Standards

SML

Smart Meter Language Protocol Version 1.04

IEC62056-21

IEC mode A, B and D (on request)

General Characteristics

Product

iO881A

Storage Temperature

-40°C to +85°C

Operating Temperature

T5°C to +55°C

Mounting

Via integrated magnet

Housing

Material: ABS, black
Dimension: 47mm x 34mm x 22mm (without connectors)

Certification

RED (2014/53/EC)
RoHS Directive (2011/65/EC)

LoRaWAN

® 

1.0.2

Summary of Contents for 404620

Page 1: ...MST GmbH Carl Friedrich Gau Str 2 4 D 47475 Kamp Lintfort iOKE868 LoRaWAN User Manual Version 1 0 Document State initial Date October 2020 Document ID 4000 40140 160 2020 IMST GmbH All rights reserved...

Page 2: ...f 12 History Version Date Comment 1 0 October 2020 Initial Version Content General User Information Hardware Overview iO881A Startup Reader Functions Real Time Clock Synchronization LED and Push Butto...

Page 3: ...explicit nor implicit is given for the correctness at the time of publication IMST GmbH reserves all rights to make corrections modifications enhancements and other changes to its products and servic...

Page 4: ...s do so at their own risk Any resale of IMST GmbH products or services with statements different from or beyond the parameters stated by IMST GmbH for that product solution or service is not allowed a...

Page 5: ...an overview about the hardware of iOKE868 iOKE868 LoRaWAN consist of iO881A for LoRaWAN antenna micro USB cable Figure iO881A for LoRaWAN antenna and USB cable Features of iO881A USB interface for gen...

Page 6: ...cult RF environments Power Supply The iO881A is supplied via the Micro USB interface The configured iO881A can be supplied by an additional USB power supply or battery pack Interfaces of iO881A Push b...

Page 7: ...alender Events and OBIS ID Filter have to be set to change the iO881A behavior Note the LoRaWAN Stack can be deactivated and reactivated again Step 3 LoRaWAN Stack Activation OTAA or ABP In case of Ov...

Page 8: ...ement value within this record The OBIS ID Scan Mode can be activated to read and forward only the published OBIS IDs of the connected meter The captured OBIS IDs will be sent as a list via wired loca...

Page 9: ...value is used to configure the RTC and is finally stored in the NVM for later usage after a system reset Due to the fact that some LoRaWAN server do not support the Get Time MAC Command a fall back m...

Page 10: ...en 1 x Not used LoRaWAN stack activated Nothing iO881A is ready for meter data reading Red 2 x Read error or no data LoRaWAN configuration invalid or not activated Connect iO881A to PC and start confi...

Page 11: ...equires an initial configuration before usage This configuration can be done by means of a PC Tool called WS Configurator which is connected via serial interface USB to the device For further informat...

Page 12: ...Antenna Via MMCX connector LoRa Protocol Characteristics LoRaWAN Certified and compliant to V 1 0 2 Activation type ABP activation by personalization OTAA over the air activation Frequencies Standard...

Reviews: