![IMS TIG 131 HF Manual Download Page 13](http://html.mh-extra.com/html/ims/tig-131-hf/tig-131-hf_manual_2049895013.webp)
290910- S112-73516
13/40
Recommended combinations / Electrode grinding
Current (A)
Ø Electrode (mm)
= Ø wire (filler metal)
Ø Nozzle (mm) Flow rate (Argon L/mn)
0,5-5
10-130
1,6
9,8
6-7
4-6,5
130-200
2,4
11
7-8
To optimise the welding process, it is recommended to grind the electrode prior to welding as described in the
diagram below :
d
l
Trigger command connector
The trigger command socket is laid out in the following way:
DUTY CYCLE
The welding unit describes an output characteristic of a "constant current". The duty cycles following the norm
EN60974-1 (at 40°C on a 10mn cycle) are indicated in the table below :
Note : The machines’ duty cycle has been tested at room temperature (40°C) and has been determined by
simulation.
L = 3 x d for a low current
L = d for a high current
L
IMS TIG 131
Switch GND
Welding torch button
3
2
4
5
1
IMS TIG 161
Cold current button
Switch GND
Welding torch button
IMS TIG 200
Cold current button
Switch GND + Potentiometer
Welding torch button
Cursor / potentiometer
+5V potentiometer
IMS TIG 161
X% @ I max X% @
I max
21%
160A
15%
160A
60%
100A
60%
80A
100%
90A
100%
70A
IMS TIG 131
X% @ I max X% @
I max
24%
130A
15%
130A
60%
75A
60%
65A
100%
70A
100%
60A
IMS TIG 200 (230V)
X% @ I max X% @
I max
30%
200A
20%
200A
60%
140A
60%
125A
100%
125A
100%
110A
IMS TIG 200 (110V)
X% @ I max X% @
I max
26%
180A
30%
120A
60%
115A
60%
90A
100%
100A
100%
80A