CONTROL PANEL DESCRIPTION
1
General ON/OFF switch
2
Power setting buttons
3
Power indicator (1kW – 5 kW).
4
Induction heating activation
5
Alarm indicator – Cooling circuit
6
Heating indicator (ON=heating; blinking = stand-by).
7
Heat switch
8
Inductor (ferrite)
9
Cooling liquid temperature alarm (machine stopped)
10
Inductor alarm (wrong inductor or short-circuit)
« Alarm » indicators :
The alarm indicators above mean, from left to right :
1. A cooling liquid temperature which is too high. Leave the product ON without using the inductor, in order for
the cooling liquid temperature to decrease.
2. An issue with the flow of cooling liquid (pump issue, blocked pipe).
3. A defective inductor; contact JBDC after sales or your local distributor.
Note : in case of alarm, the product does not heat up.
053410_01 01 2015_V1.1
- 6 -