![impro IXP20 Installation Manual Download Page 8](http://html1.mh-extra.com/html/impro/ixp20/ixp20_installation-manual_2049686008.webp)
ISC304-0-0-GB-06
April 2011
Page 8
DIP-switch Position
Connections
8
Wiegand Open Format.
9
If the ImproX RF is connected, then Button 1 of the
ImproX (QT) Quad Transmitter reports.
10
If the ImproX RF is connected, then Button 2 of the
ImproX (QT) Quad Transmitter reports.
11
If the ImproX RF is connected, then Button 3 of the
ImproX (QT) Quad Transmitter reports.
12
If the ImproX RF is connected, then Button 4 of the
ImproX (QT) Quad Transmitter reports.
Table 1: Reader 1 Select and Reader 2 Select DIP-switch Settings
Door Lock Select DIP-switch Settings
DIP-switch Position
Connections
0
Reserved.
1
Reserved.
2
Reserved.
3
Reserved.
4
Reserved.
5
Returns Controller to Factory Default Settings.
NOTE:
Return Switch 1 to the OFF position to
resume normal operation.
Table 2: Door Lock Select DIP-switch Settings