impro IXP20 Installation Manual Download Page 4

 

ISC304-0-0-GB-06 

April 2011 

Page 4 

 

 

Display (ISC921 Only) 

 

 

 

Type ...............................  

Thin Film Transistor Liquid Crystal Display 
(TFT-LCD). 

 

 

Resolution.......................  

240 x 320 Pixels. 

 

 

Colour .............................  

65 K Colour Screen. 

 

 

Back-lighting ...................  

Permanently on. 

 

Status LED 

 

 

Power On........................  

Continuous Red. 

 

Upgrade Mode ................  

Flashing Red. 

 

Incoming RS485 Data ............  

Flashing Green LED. 

 

Outgoing RS485 Data ............  

Flashing Red LED. 

 

Digital Inputs (1-4) ..................  

Continuous Green on detected contact 
closure. 

 

Relays (1 and 2) .....................  

Continuous Red on activation of the Relay. 

 

Locked ...................................  

Continuous Green when locked. 

 

Unlocked ................................  

Continuous Green when unlocked. 

 

Enet Act (Ethernet Activity) ....  

Flashing Red LED. 

 

Enet Spd (Ethernet Speed) ....  

Continuous Red for 100 Mbps (Default)  
Off for 10 Mbps. 

 

Enet Lnk (Ethernet Link) ........  

Continuous Red on connection to network. 

INSTALLATION INFORMATION 

Accessories 

CAUTION: 

The IXP20 Controller needs a standard Ethernet cable to connect to 
a PC.  We do NOT however supply this cable with the Controller’s 
accessories. 

Find the following when unpacking the ImproX IXP20 Controller: 

 

Either an ImproX IXP20 Twin Reader Controller with Web Interface (ISC920) 
supplied in a Black ABS Plastic housing.  The housing consists of a Front Cover 
Assembly and a Mounting Plate.  The Front Cover and Mounting Plate are held 
together with two Combi Screws (M4 x 10 mm) at the bottom of the housing.  

 

There are also two spare Combi Screws (M4 x 10 mm). 

 

Or, an ImproX IXP20 Twin Reader Controller with Touch Screen (ISC921) 
supplied in a Black ABS Plastic housing.  The housing consists of a Front Cover 
Assembly and a Mounting Plate.  The Front Cover and Mounting Plate are held 
together with two Combi Screws (M4 x 10 mm) at the bottom of the housing.  

 

There are also two spare Combi Screws (M4 x 10 mm). 

CAUTION: 

DO NOT use the Metal-oxide Varistors (25 Vrms, 500 A, 77 V max 
clamping) with mains power applications. 

 

Three Metal-Oxide Varistors, 25 Vrms, 500 A, 77 V max clamping. 

 

A 3 V, CR2032, Lithium cell Battery. 

Summary of Contents for IXP20

Page 1: ...connected and relays off 75 0 90 24 V DC with no peripherals connected and relays off 40 0 96 Power Requirements ISC921 12 V DC with no peripherals connected and relays off 130 1 56 24 V DC with no p...

Page 2: ...discipline Reader and Wiegand Readers The function is selectable via the DIP switches See Table 1 Power Output 12 V DC and 5 V DC selectable at maximum 200 mA Modes Supported Tag PIN code or Reason Co...

Page 3: ...Input monitors a constant resistance through the circuit When the circuit is tampered with the Resistors are bypassed the Controller detects the resistance change raising an alarm Door Lock Type 2 Dry...

Page 4: ...o a PC We do NOT however supply this cable with the Controller s accessories Find the following when unpacking the ImproX IXP20 Controller Either an ImproX IXP20 Twin Reader Controller with Web Interf...

Page 5: ...with Impro Wiegand Readers use the 12 V power output option Note however that the Multi discipline Readers only connect using the 12 V power output option For maximum data communications distance inst...

Page 6: ...ttery Tab 3 Pull the removable Battery Tab out of the Battery Holder 4 Immediately apply power to the Controller Replacement NOTE Because of the delicacy of this procedure we recommend you contact you...

Page 7: ...tandard Wiegand Readers can only support one of two options HID Tags only or any other Tag type that is Slim Tags Omega Tags Mifare Standard Mifare Ultralite FeliCa Desfire WriTag 128 and WriTag 2048...

Page 8: ...Button 3 of the ImproX QT Quad Transmitter reports 12 If the ImproX RF is connected then Button 4 of the ImproX QT Quad Transmitter reports Table 1 Reader 1 Select and Reader 2 Select DIP switch Sett...

Page 9: ...he number to be a tag code The Controller discards the previously read Tag for the current one and the Controller will still expect a PIN code If the IXP20 Controller expects a Reason Code and receive...

Page 10: ...ISC304 0 0 GB 06 April 2011 Page 10 ELECTRICAL CONNECTIONS Key Component Positions Figure 3 IXP20 Controller Key Component Positions...

Page 11: ...C304 0 0 GB 06 April 2011 Page 11 Connecting the IXP20 Controller Figure 4 shows a typical electrical connection diagram for the IXP20 Controller Figure 4 Typical IXP20 Controller Electrical Connectio...

Page 12: ...ISC304 0 0 GB 06 April 2011 Page 12 Figure 5 IXP20 Controller connected to Wiegand Reader...

Page 13: ...ISC304 0 0 GB 06 April 2011 Page 13 Figure 6 IXP20 Controller connected to ImproX RF...

Page 14: ...utomatically clears the System Database on the next restart 1 Remove the Controller s Front Cover Assembly 2 With power applied to the Controller toggle switch 1 of the Door Lock Select DIP switch ON...

Page 15: ...e Terminals appear during the Software s Auto ID process MAC Address Figure 7 Sample MAC Address Label Each IXP20 Controller is supplied with a separate MAC Address Label much like the one shown in Fi...

Page 16: ...ISC304 0 0 GB 06 April 2011 Page 16 Fixed Address Label Unique Location Description...

Page 17: ...ISC304 0 0 GB 06 April 2011 Page 17 Fixed Address Label Unique Location Description...

Page 18: ...ISC304 0 0 GB 06 April 2011 Page 18 Fixed Address Label Unique Location Description...

Page 19: ...n Chart GUARANTEE OR WARRANTY CAUTION We reserve the right to nullify the products guarantee or warranty where you have not properly installed the Metal oxide Varistors This product conforms to our Gu...

Page 20: ...to the ImproX IXP20 Controller ISC920 0 0 GB 03 and ISC921 5 0 GB 03 The last two digits of the Impro stock code indicate the issue status of the product ISC304 0 0 GB 06 Issue 07 Apr 2011 IXP20 Cont...

Reviews: