MODEL NUMBER:
SGI911-1-1-GB-XX
I
MPRO
X
S
UPA
G
ATE
ImproX SupaGate 4-Channel Controller
INSTALLATION MANUAL
SPECIFICATIONS
Working Environment
.................
The SupaGate is designed to work in an
indoor or protected outdoor environment
similar to IP20. The SupaGate is, therefore,
NOT sealed against water.
Passive Frequency
......................
125 kHz.
RF Frequency
...............................
433.92 MHz.
Security
........................................
ImproX DCT, Dynamic Code Transmission
Technology.
Input Voltage
................................
10 V DC to 14 V DC.
Power Requirements
Current (mA)
Power (W)
Input Voltage 12 V DC,
1 Antenna Reader, all
Relays OFF ............................
60
0.72
Input Voltage 12 V DC,
1 Antenna Reader, all
Relays ON ..............................
220
2.64
Relays
Relay Output ..........................
4 Relays, each with NO, COM and NC
contacts.
Relay Contact Ratings ...........
10 A at 28 V DC,
5 A at 220 V AC.
Installer Interfaces
LED Indicators
7-Segment Display .........
2 Displays, Red (externally visible).
Push-buttons ..........................
4 Push-buttons (externally accessible).