Summary of Contents for IWA05KSP

Page 1: ......

Page 2: ...on of Power Cord Current Device 11 Air Conditioner Features and Operation Instructions 11 Care and Cleaning 16 Additional Things You Should Know 17 Troubleshooting Tips 19 ESTE MANUAL ES TAMBIÉN DISPONIBLE EN ESPAÑOL Y SE PUEDE DESCARGAR EN WWW IMPECCAUSA COM THIS MANUAL IS ALSO AVAILABLE IN SPANISH AND CAN BE DOWNLOADED AT WWW IMPECCAUSA COM ...

Page 3: ...y and or property damage please familiarize yourself with the following instructions and safety precaution Failure to comply with the instructions and cautions mentioned in this manual may cause harm or damage The seriousness is classified by the following indications This symbol indicates the possibility of serious injury or death This symbol indicates the possibility of injury and or damage to p...

Page 4: ... 3 WHAT S IN THE BOX 1 AC Unit 2 Remote control 3 User s Guide 4 Remote control user s guide not shown 5 Window Installation Kit not shown 2 1 3 ...

Page 5: ... Do not allow water to run into internal electric parts Always install circuit breaker and a dedicated power circuit Incorrect grounding may cause electric shock Doing so may cause failure of the unit and or electric shock Incorrect installation may cause fire and or electric shock Unplug the unit if you notice strange sounds smells or smoke coming from it Do not use the socket if it is loose or d...

Page 6: ...do so may result in damage as water may seep in or electrical overload may occur Failure to turn off unit first may result in shock Doing so will help preserve the lifespan of this unit Ensure that the installation bracket is not damaged due to prolonged exposure to outdoor elements Always insert the filters securely Clean filter routinely Do not use strong detergents waxes or thinners to clean Us...

Page 7: ...ted on the side of the cabinet and behind the grille Be sure the air conditioner is properly grounded To minimize shock and fire hazards proper grounding is important The power cord is equipped with a three prong grounding plug for protection against shock hazards Do not remove any of the prongs from the power cord Your air conditioner must be used in a properly grounded wall receptacle If the wal...

Page 8: ... Save original carton and these installation instructions for future reference The carton is the best way to store the unit during winter or when the unit will not be used for an extended period of time Mounting Hardware TOOLS NEEDED Phillips Screw Driver Drill if pilot holes are needed Caution When handling unit be careful to avoid cuts from sharp metal edges and aluminum fins on front and rear c...

Page 9: ...nstalled the flange for securing the panel in place to the windowsill will be facing into the room FIG 3C 3 Align the hole in the top rail with those in the top of the unit as shown in Figure B 4 Secure the top rail to the unit with the 3 8 screws as shown in Figure C Note For safety reasons all four 4 screws MUST be securely fastened Hold the Accordion Panel in one hand and gently pull back the c...

Page 10: ...as been installed on the side of the cabinet make sure it sits securely inside the frame channel by making slight adjustments Slide the top and bottom ends of the frame into the top and bottom rails of the cabinet Figure 4 Note If storm window blocks AC see Figure 13 4 Place the frame lock between the frame extensions and the windowsill as shown in Fig 7 Drive 19mm or 13mm locking screws through t...

Page 11: ...lots are not caulked or painted shut Accumulated rainwater or condensation must be allowed to drain out Sash Storm window frame or other obstruction 1 Min 38mm Board thickness as required for proper pitch to rear along entire sill Fasten with nails or screws Removing AC from Window Turn AC off and disconnect power cord Remove sash seal from between windows and unscrew safety lock Remove screws ins...

Page 12: ...placed if it fails reset when either the TEST button is pushed or if it cannot be reset A new one can be obtained by contacting technical support If power supply cord is damaged it cannot be repaired It MUST be replaced by one obtained from the product manufacturer AIR CONDITIONER FEATURES AND OPERATION INSTRUCTIONS Before you begin thoroughly familiarize yourself with the control panels as shown ...

Page 13: ...lay This temperature will be automatically maintained anywhere between 62 F 17 C and 86 F 30 C If you want the display to read the actual room temperature refer to the note To Operate on Fan Only Press to Raise Temperature Press to Lower Temperature Press to select appropriate fan speed Select the Fan Speed in four steps Auto Low Med or High Each time the button is pressed the fan speed mode is sh...

Page 14: ... such as for room air circulation or to exhaust stale air on some models Remember to open the vent during this function but keep it closed during cooling for maximum cooling efficiency You can choose any fan speed you prefer During this function the display will show the actual room temperature not the set temperature as in the cooling mode In Fan Only mode the temperature is not adjusted To opera...

Page 15: ...ated When the time of TIMER ON is displayed press the Timer button again the TIMER OFF indicator light illuminates It indicates the Auto Stop program is initiated Press or hold the UP or DOWN button to change the Auto time by 0 5 hour increments up to 10 hours then at 1 hour increments up to 24 hours The control will count down the time remaining until start The selected time will register in 5 se...

Page 16: ...in If error repeats call for service NOTE is displayed as shown in the left picture HS Electric heating sensor error Unplug the unit and plug it back in If error repeats call for service Light flashes on control panel when activated NOTE This feature can only be activated from the remote control When activated the remote control serves as a remote thermostat allowing for the precise temperature co...

Page 17: ...ashing you may vacuum the filter clean Note Never use hot water over 40 C 104 F to clean the air filter Never attempt to operate the unit without the air filter Cabinet Cleaning Be sure to unplug the air conditioner to prevent shock or fire hazard The cabinet and front may be dusted with an oil free cloth or washed with a cloth dampened in a solution of warm water and mild liquid dishwashing deter...

Page 18: ...Operation Outdoor Temp 18 43 C T1 Environment 21 52 C T3 Environment Indoor Temp 17 32 C T1 Environment 17 32 C T3 Environment Heating Operation Outdoor Temp 5 24 C T1 Environment 7 24 C T3 Environment Indoor Temp 0 27 C T1 Environment 0 30 C T3 Environment Performance may be reduced if unit is operated above or below these operating temperature ranges High Pitched Chatter High efficiency compress...

Page 19: ... 18 Air Directional Louvers The louvers will allow you to direct the airflow Left or Right as needed Move the levers from side to side until the desired airflow direction is obtained Lever Air Direction ...

Page 20: ...art when in the COOL mode Air conditioner cooling but room is too warm ice forming on cooling coil behind decorative front panel 1 Outdoor temperature below 18 C 64 F To defrost the coil set to FAN ONLY mode 2 Air filter may be dirty Clean filter Refer to Care and Cleaning section 3 Thermostat set too cold for night time cooling To defrost the coil set to Fan Only mode and then set temperature to ...

Page 21: ...re from humid room This is normal during excessively humid days Remote sensing PMTS Personal Mapping Temperature Sensor deactivating prematurely 1 Remote control not located within range Place remote control within 20 feet and 180 radius of the front of the unit 2 Remote control signal obstructed Remove obstruction Room too cold 1 Temperature setting is too low Increase the temperature setting If ...