ADDITIONAL FEATURES EXPLAINED:

TIMER FUNCTION (Delay Start and/or Stop)

  The timer can be used for two separate functions: 

• 

To set a time delay before the unit will power on.

• 

To set a time delay before the unit will power off. 

NOTE

: Both can be set together.

Setting the unit to automatically turn off:

• 

With the dehumidifier running, push the timer 

button once (twice if dehumidifier is not run

-

ning), until the ‘OFF’ indicator illuminates.

• 

Use the  

 and 

  buttons to select the number of 

hours until the unit will power off.

• 

The time will be programmed after 5 seconds of 

inactivity and the display will return to show the 

humidity level. 

Setting the unit to automatically turn on:

• 

With the dehumidifier not running, push the 

timer button once (twice if dehumidifier is not 

running), until the ‘ON’ indicator illuminates.

• 

Use the 

 and 

  buttons to select the number of 

hours until the unit will power off.

• 

The time will be programmed after 5 seconds of 

inactivity and the display will return to show the 

humidity level.

NOTES:

 

• 

If both an “ON” and “OFF” program were set, 

both respective indicators will be illuminated. 

• 

The amount of hours chosen is from the time the 

program was set. 

• 

To check the program, simply press the TIMER 

button again to cycle through ON and OFF times 

accordingly.  

TURBO MODE (If equipped)

• 

If pressed, the indicator will illuminate.  This will 

provide a quicker dehumidification.  Ideal for 

situations where speedy removal of moisture is 

more important than quiet operation. 

RESERVOIR FULL LIGHT

• 

Illuminates when the reservoir is full and ready 

to be emptied, or when the reservoir is removed 

and not seated in the proper position.

AUTO SHUT OFF

  The dehumidifier shuts off after 30 seconds when:

• 

The reservoir is full.

• 

The reservoir is removed or not seated in the 

proper position. 

• 

When the desired humidity level is reached.

NOTE

: On some models, the fan motor will con

-

tinue operating.

CHECK FILTER

• 

The system keeps count when the fan motor op

-

erates and illuminates the clean filter light after 

250 hours of operation (about every 10 days if in 

continuous use). The  indicator light flashes once 

per second. 

• 

 After cleaning the air filter, press the FILTER but

-

ton on the control panel and the indicator turns 

off.

AUTO DEFROST

• 

When frost builds up on the evaporator coils, the 

compressor will cycle off and the fan will contin

-

ue to run until the frost disappears.

AUTO PROTECT

• 

Once the unit is turned off, it can not restart oper

-

ation for the first 3 minutes. This is to protect the 

unit. Operation will automatically resume after 3 

minutes.

AUTO RESTART

• 

If the household power goes out, the unit will 

automatically resume the previous mode and 

settings when power returns.

 $$$ SAVE & CONSERVE ENERGY

• Use the unit in the recommended room size.
• Locate the unit where furniture cannot obstruct the air flow.
• Keep the filters clean.
• Keep doors and windows closed.

Summary of Contents for IDM-95TEP-95

Page 1: ...Dehumidifier User s Manual Model IDM 95TEP 95 Pint Dehumidifier v 1 0 www impecca com...

Page 2: ...old appliance for disposal at least free of charge to the user D As old products contain valuable resources they can be sold to scrap metal dealers Wild disposal of waste in forests and landscapes end...

Page 3: ...y start and stop NOTE Due to slight modifications in production the instructions features and or descriptions found in this manual might vary slightly from your product SAVE TIME AND MONEY If you revi...

Page 4: ...re the receptacle is accessible after the unit installation Do not exceed the rating of the power out let or connection device Do not operate or stop the unit by switching on or off the power Do not d...

Page 5: ...the power cord and take care so that the cord is not compressed Do not climb up on or sit on the unit It may cause electric shock or failure of appliance There is danger of fire or electric shock You...

Page 6: ...hes dryers heaters or radiators Use the unit to prevent moisture damage anywhere books or valuables are stored The dehumidifier should be operated in an enclosed area to be most effective Close all do...

Page 7: ...NUOUS MODE In continuous mode the unit s compressor will run continuously until the unit is powered off or another mode is selected This will remove all the moisture from the air that it s capable of...

Page 8: ...to avoid damage to the dehumidifier do not touch any parts inside after removing the reservoir Be sure to push the reservoir gently all the way into the unit as putting it in roughly can cause problem...

Page 9: ...ing sure that there are no kinks that will stop the water flow Place the end of the hose into the drain and make sure the end of the hose is level or down to let the water flow smoothly The pump is po...

Page 10: ...tor will illuminate This will provide a quicker dehumidification Ideal for situations where speedy removal of moisture is more important than quiet operation RESERVOIR FULL LIGHT Illuminates when the...

Page 11: ...rvoir After clean ing the reservoir must be in place and securely seated for the dehumidifier to operate CLEANING THE AIR FILTER Clean the filter every two weeks based on normal operating con ditions...

Page 12: ...rs on the coils This is normal The dehumidifier has an auto defrost feature Water on floor Hose to connector or hose connection may be loose Even though you re using the reservoir the back drain plug...

Reviews: