3.3 Mounting
The ISS360 should be mounted using clamps around the mid-section of the body. The body has a
20mm recess to allow a clamp to be tightened securely around the unit.
When mounting the Acetal version of the ISS360, ensure excessive mounting force is not used.
A non-metallic clamp should be used. In the event this is not possible, effort should be made to
electrically isolate the clamp from the ISS360 housing.
This can be achieved by using rubber or plastic strips around the body of the ISS360.
The ISS360 has two flats on either side of the connector endcap end of the body. These are to
enable the unit to sit tightly against another flat surface if available. These flats also help prevent
the sonar moving when on the workbench for testing.