13
CLEAR MEMORY POSITIONS
Step
Operation
Result
1
Press
s
or
t
to awaken controller.
Desk height displays on screen.
2
Press and hold
st
simultaneously for 5+ sec-
onds.
Small “house” icon displays in bottom left corner. Make sure to press
arrows at precisely the same time. If the “house” icon doesn’t appear,
retry until it does.
3
Press
t
to drive desk to lowest height.
Memory positions cleared.
Step
Operation
Result
1
Press
s
or
t
to awaken controller.
Desk height displays on screen.
2
Quickly press
st
together twice.
“CM” will display. Make sure to press arrows at precisely the same time.
If “CM” doesn’t appear, retry until it does.
3
Press
s
once.
(“) will display.
4
Press
st
again.
Display set to Inches (in).
CHANGE DISPLAY UNITS FROM CENTIMETERS (CM) TO INCHES (IN)
MOVE TO MEMORY POSITIONS
Step
Operation
Result
1
Press and hold
s
or
t
arrow.
Desk raises/lowers until reaching saved position.
This procedure is the same as the Initial Calibration.
Step
Operation
Result
1
Press
t
to drive desk to lowest height.
Desk rests at lowest position.
2
Measure distance from floor to table top surface.
Proceed if variance exists between your measurement and display
height.
3
Press
st
together once.
“Un” displays on screen.
4
Press
s
once.
“CAL” displays on screen.
5
Press
st
together once.
Height displayed, flashing.
6
Press
s
or
t
until display shows correct height.
Correct height displayed.
7
Press
st
together once.
“CAL” displays on screen.
8
Press
t
twice.
Handset calibrated to correct height. Saved.
VERIFY YOUR HANDSET DISPLAYS CORRECT HEIGHT