i³ 

Creating a Program 

 
Creating a New program, Saving  a program  or Opening an existing program, all 
done in the file menu. 
 

 

Click on the icon or select from the menu

Click on the icon or select from the menu

Click on the icon or select from the menu

Recently opened programs 

 
The program file name format is “program_name” followed by the extension .csp 
For example,  program_name.csp 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

No part of this publication may be reproduced without the prior agreement and written permission of IMO Precision Controls Ltd. 
Information in this document is subject to change without notice.

 

 

11 

Summary of Contents for i3A12X/10A01-SOO

Page 1: ...i Display Control Connect User Guide...

Page 2: ...Creating a Program 11 Example 12 Program Options 17 Example 18 Running and Monitoring the i3 Program 18 i3 Help File 20 Appendix A Data Types 21 Appendix B i3 Register Types 22 Appendix C System Bits...

Page 3: ...e i3 can be used to perform advanced machine control factory machine monitoring and process control Guide to Part Numbers Model Number Digital Inputs Analogue Inputs Digital Outputs Analogue Outputs H...

Page 4: ...c com Double click on the icon with the right mouse button to open the installation program Follow the steps in the installation wizard to install the i3 Configurator to your PC No part of this public...

Page 5: ...i No part of this publication may be reproduced without the prior agreement and written permission of IMO Precision Controls Ltd Information in this document is subject to change without notice 4...

Page 6: ...program box and click Finish No part of this publication may be reproduced without the prior agreement and written permission of IMO Precision Controls Ltd Information in this document is subject to c...

Page 7: ...left When power is applied the i3 will then run a system diagnostic before running the user program No part of this publication may be reproduced without the prior agreement and written permission of...

Page 8: ...t Tour of the i3 Configurator To launch the i3 Configurator program either select the option from the Programs menu in Windows or double click the icon on the desktop with the right mouse button No pa...

Page 9: ...elp File Programming elements Edit screens menu Verify Download Upload the program Configure the Controller Set comm Parameters RUN the controller Open existing programs Save programs Create New progr...

Page 10: ...are two ways to configure the controller manually or automatic With an i3 connected to the PC the easiest method is to Auto Config Automatic Click on the Auto Config button A warning pop up will appea...

Page 11: ...h the right mouse button and then select the type of controller from the pull down list Then select the correct model number No part of this publication may be reproduced without the prior agreement a...

Page 12: ...ect from the menu Click on the icon or select from the menu Recently opened programs The program file name format is program_name followed by the extension csp For example program_name csp No part of...

Page 13: ...g the Boolean elements insert contacts and coils to make the following latching ladder diagram Variable Name Address Type EM_STOP I0001 NC CONTACT START K0001 NO Function Key STOP K0002 NO Function Ke...

Page 14: ...menu pops up click the screen button Click here Now click Edit screen Select the top left screen No part of this publication may be reproduced without the prior agreement and written permission of IMO...

Page 15: ...ght click on the screen Double click on the word box to open up the properties No part of this publication may be reproduced without the prior agreement and written permission of IMO Precision Control...

Page 16: ...e string STOPPED to the value 0 Click OK Click Add again and assign the string RUNNING to the value 1 Finally click OK to exit the Text Table Entry No part of this publication may be reproduced withou...

Page 17: ...e the graphic edit by clicking on the cross at the top right of the window Click OK and the I O point pop up window The ladder diagram will now look like the diagram below No part of this publication...

Page 18: ...good idea to Error Check the program before downloading Click the icon or select from the menu The error check gives the user a report on the project and lists any errors found No part of this public...

Page 19: ...m The i3 will be by default in STOP mode and requires to be put into RUN mode for the programmed i3 to operate Start Pause Stop Either use the icons or select from the menu No part of this publication...

Page 20: ...icon When the program is being monitor made contacts and coils are shown in red No part of this publication may be reproduced without the prior agreement and written permission of IMO Precision Contro...

Page 21: ...is to know on the i3 to open the Help file either use the menu or press F1 No part of this publication may be reproduced without the prior agreement and written permission of IMO Precision Controls Lt...

Page 22: ...Integers are used where the value of the data is expected to be in the range of 2 147 483 648 to 2 147 483 647 UINT Unsigned Integer A 16 bit unsigned value Unsigned Integers are used where the value...

Page 23: ...m the CAN in from other OCS WORD YES 32 per node AQG Global Analog Outputs to the CAN out to other OCS WORD NO 32 per node T Internal Temporary bits use for contacts and coils BOOL NO 2048 M Internal...

Page 24: ...Version 3 System Screen Number 0 10 41 LCD Columns 4 Self Test Result 42 LCD Rows 5 Controller Mode RUN 0 2 43 Keypad Type 6 Scan Rate Avg 44 RTC Seconds 0 59 7 Reserved 45 RTC Minutes 0 59 8 Reserved...

Page 25: ...tem Beep 0 1 30 Network Baud Rate 0 3 184 User Beep 0 1 31 Network Required 0 1 185 Screen Saver 0 1 32 LCD Contrast 1 255 186 Screen Saver Time 5 1200 33 Key Toggle Mode 0 1 187 Network Usage Avg 0 1...

Page 26: ...Information in this document is subject to change without notice 25 IMO Canada Tel 905 265 9844 Fax 905 265 1749 IMO Precision Controls United Kingdom Tel 44 0 20 8452 6444 Fax 44 0 20 8450 2274 IMO...