![IMO Precision Controls Jaguar VXS User Manual Download Page 27](http://html1.mh-extra.com/html/imo-precision-controls/jaguar-vxs/jaguar-vxs_user-manual_2048178027.webp)
66
Electronic thermal
(Motor 2)
—
—
0
overload 2 — mode
0 = Inactive
(for Electronic thermal o/l 1 1 or 3 = Active (standard 4-pole motors)
see F15/16)
2 or 4 = Active (inverter-rated motors)
67
Electronic thermal
(Motor 2) 0.01 to 99.9
0.01 to 9.99
A
0.01
*
overload 2 — level
10.0 to 99.9
0.1
0.01 to 99.9 = 20% to 105% of inverter rated current
* Default factory-set at rated current for a 4-pole standard motor for each inverter frame size.
68
Slip compensation
0 = Inactive
Hz
0.1
0.0
0.1 to 5.0 = Active
69
Torque vector control
0 = Inactive
—
—
0
1 = Active
70
Motor 1 capacity
0 = One size larger than standard
—
—
1
(frame size)
1 = Standard frame size for the inverter
2 = One size below
3 = Two sizes below
71
Rated current 1
(Motor 1) 0.01 to 99.9
0.01 to 9.99
A
0.01
*
10.0 to 99.9
0.1
72
No-load current 1
(Motor 1) 0.01 to 99.9
0.01 to 9.99
A
0.01
*
10.0 to 99.9
0.1
73
Rated current 2
(Motor 2) 0.01 to 99.9
0.01 to 9.99
A
0.01
*
10.0 to 99.9
0.1
* Default factory-set at rated current for a 4-pole standard motor for each inverter frame size.
74
Automatic tuning
0 = Inactive
—
—
0
1 = Active
75
Tuning %R value
0.00 to 50.00
%
0.01
*
76
Tuning %X value
0.00 to 50.00
%
0.01
*
* Default factory-set at rated value for a 4-pole standard motor for each inverter frame size.
77
Torque limiter response
000 to 999
—
—
369
— constant speed
78
Torque limiter response
000 to 999
—
—
394
— during accel./decel.
79
Option selector
0 = No options installed
—
—
0
1 = DI option card
2 = DI/O option card
3 = RS option card
Please consult IMO Precision Controls Ltd for details of options.
Function
Setting Range
Unit Resol. Def.
No.
Name
Functions in
can be adjusted while the inverter is running. Data in […] applies to three phase inverters.
Resol. = resolution; Def. = Factory-set defaults — refer to Function 39.
25
Summary of Contents for Jaguar VXS
Page 1: ......