40
STZSkW ed 12/07
ZEUS Superior kW
Technical Documentation
Technical Documentation
Combustion parameters.
G20
G30
G31
Zeus Superior 24 kW
Gas nozzle diameter
mm
1,35
0,79
0,79
Supply pressure
mbar (mm H
2
O)
20 (204)
29 (296)
37 (377)
Flue flow rate at nominal heat output
kg/h
50
49
51
Flue flow rate at minimum heat output
kg/h
50
48
49
CO
2
at Q. Nom./Min.
%
7,50 / 2,90
8,70 / 3,50
8,30 / 3,40
CO at 0% of O
2
at Q. Nom./Min.
ppm
73 / 93
88 / 116
62 / 113
NO
X
at 0% of O
2
at Q. Nom./Min.
ppm
138 / 75
186 / 83
181 / 87
Flue temperature at nominal heat output
°C
115
118
114
Flue temperature at minimum heat output
°C
98
102
100
Zeus Superior 28 kW
Gas nozzle diameter
mm
1,35
0,79
0,79
Supply pressure
mbar (mm H
2
O)
20 (204)
29 (296)
37 (377)
Flue flow rate at nominal heat output
kg/h
58
55
57
Flue flow rate at minimum heat output
kg/h
61
59
60
CO
2
at Q. Nom./Min.
%
7,50 / 2,94
9,10 / 3,55
8,70 / 3,46
CO at 0% of O
2
at Q. Nom./Min.
ppm
97 / 104
179 / 103
90 / 99
NO
X
at 0% of O
2
at Q. Nom./Min.
ppm
123 / 77
184 / 89
168 / 88
Flue temperature at nominal heat output
°C
108
115
111
Flue temperature at minimum heat output
°C
79
82
81
Zeus Superior 32 kW
Gas nozzle diameter
mm
1,35
0,79
0,79
Supply pressure
mbar (mm H
2
O)
20 (204)
29 (296)
37 (377)
Flue flow rate at nominal heat output
kg/h
66
66
68
Flue flow rate at minimum heat output
kg/h
66
66
69
CO
2
at Q. Nom./Min.
%
7,40 / 2,90
8,50 / 3,40
8,20 / 3,20
CO at 0% of O
2
at Q. Nom./Min.
ppm
58 / 89
50 / 25
30 / 20
NO
X
at 0% of O
2
at Q. Nom./Min.
ppm
119 / 65
153 / 84
167 / 137
Flue temperature at nominal heat output
°C
119
121
118
Flue temperature at minimum heat output
°C
95
96
92