ZEUS Superior kW
Technical Documentation
Technical Documentation
Signals and anomalies.
6
Malfunction signalled
Error code Display
Super CAR Display
CAR Display
No ignition malfunction
ERR 01
ERR 01
E01
Safety thermostat block
(over-temperature)
,
flame control anomaly
ERR 02
ERR 02
E02
Fan anomaly
ERR 03
ERR 03
E02 + E03
Contacts resistance block
ERR 04
ERR 04
E02 + E04
Flow probe anomaly
ERR 05
ERR 05
E05
Insufficient system pressure
ERR 10
ERR 10
E10
Flue flow meter anomaly
ERR 11
ERR 11
E11
Storage tank probe anomaly
ERR 12
ERR 12
E12
Flue flow meter out of range
ERR 13
ERR 13
E13
Configuration error
ERR 15
ERR 15
E15
Incorrect fan speed
ERR 17
ERR 17
E17
Parasite flame block
ERR 20
ERR 20
E02 + E20
Push button control panel anomaly
ERR 24
ERR 24
E24
Insufficient circulation
ERR 27
ERR 27
E27
Loss of remote control communication
ERR 31
ERR 31 / CM
E31 / CON
Low voltage power supply
ERR 37
not displayed
not displayed
Loss of flame signal
38
(only displayed on VIRGILIO palmtop, or within the "M1" / "P19" menu)
The ZEUS Superior kW boiler signals any anomalies by means
of a flashing symbol (5) coupled to the indication “ERR xx”
on the indicator (6) where “xx” corresponds to the error code
described in the following table. To eliminate the block
(where
necessary)
, press the RESET button "C" positioned on the
boiler panel.