![Immergas ZENITAIR MONO Installation Manual Download Page 16](http://html1.mh-extra.com/html/immergas/zenitair-mono/zenitair-mono_installation-manual_2047922016.webp)
16
16
FUNCTIO-
NALITY
DESCRIPTION
CONTROLLER
BUTTON
ICON
LED
ACOU-
STIC
SIGNAL
Filter reset
Every 3 months a yellow warning led switches on
(fixed light) to indicate that the filters have to be
maintained. Press the dedicated button for 5 seconds
to reset the timing.
FILTER
RESET
Green
Short
Smart humidity control
When the humidity sensor detects a quick variation
of the Relative Humidity level, the running speed
automatically increases to the next higher speed.
After 10 minutes from the last quick RH variation,
the unit returns running at the selected speed. The
smart humidity control is active if the airflow di-
rection is set on alternate or extract only: if speed
5 has been selected, no speed increase happens. To
disable this functionality, press the
button for 5
seconds: on the top side of the LCD display the
symbol is shown.
F l a s h i n g
Blue
Antifrost
This functionality prevents frost building up on the
heat exchanger due to extremely cold air. When it
is activated, the unit runs in extract only at speed 1,
for 30 minutes.
Fixed Red
Acoustic signal
Any time a setting is transferred from the controller
to the unit, a short acoustic signal is emitted. This
can be deactivated by pressing the
button for 7
seconds, after when a green led flashes to indicate that
the acoustic signal is off. To reactivate the acoustic si-
gnal repeat the same operation for 7 seconds until the
led becomes green and an acoustic signal is emitted.
Green
Short
Back-Up Button
In case the remote controller gets lost or the batteries are dead,
speed 1,3 and OFF position can be selected from the on board
touch button (C). The airflow direction is always alternate and
the operation mode (either comfort or efficiency) is the last
selected from the remote controller.
SPEED
LED COLOUR
ACOUSTIC SIGNAL
Speed 1
Single Green Led
Short, Single
Speed 3
Double Green Led
Short, Double
OFF*
Red Led
Long
*press the button for 3 seconds.
Synchronisation of a number of units
It is possible to synchronized up to 10 units contemporaneously,
through wire (2 pole twisted pair type, max 30m length) so to
have mode and inversion time synchronized. When the unit is
switched on for the first time, the rotation direction of each unit
(clockwise or anti-clockwise) is automatically established. Other
functionalities like speed, smart humidity control and boost,
continue to be controlled independently on each single unit.
Wiring diagram as per fig. 16B.
Summary of Contents for ZENITAIR MONO
Page 59: ...59 59 1 60 1 1 60 1 2 60 2 61 3 62 4 65 4 1 65 4 2 65 5 66 5 1 66 5 2 66 83 84 92 BG...
Page 60: ...60 60 8 20 C 50 C 1 1 1 III 3mm B EN61032 1 2 ZENITAIR MONO VMC 150mm push pull free cooling...
Page 62: ...62 62 3 RESET RESET BOOST BOOST OFF K L K L LCD LCD IR J 1 AAA...
Page 65: ...65 65 4 4 1 49 65 4 2 L C D boost boost 15 10 5 30 boost boost 15 boost 10 7...
Page 75: ...75 75 1 76 1 1 76 1 2 76 2 77 3 78 4 81 4 1 81 4 2 81 5 82 5 1 82 5 2 82 83 84 92 RU...
Page 76: ...76 76 8 20 C 50 C 1 1 1 III 3 EN61032 1 2 ZENITAIR MONO push pull 150mm...
Page 78: ...78 78 3 K L K L J 1 AAA...
Page 79: ...79 79 40 120 120 COMFORT 70 EFFICIENCY 1 20 3 2 30 3 3 40 3 4 50 3 5 60 3 3 OFF 5 15...
Page 80: ...80 80 3 5 FILTER RESET 10 5 5 1 30 7 7 1 3 C 1 3 3...
Page 81: ...81 81 10 2 30 16B 4 4 1 49 65 4 2 15 10 5 30 15 10 7...
Page 86: ...86 86 15 16B 17 18 16A L N R R B B L N L N L N 19 20...
Page 88: ...88 88 28 29 30 31 32 34 L N 33 35...
Page 89: ...89 89 36 37 38 39 41 CLICK 40 OFF I JUNGTI ON JUNGTI...
Page 93: ...93 93 59 58 60 57 61 62...