  1  -  Position of the central heating 

temperature user adjustment

  2  -  In brackets, temperature 

value with 25°/50° range

 TM  -  Flow Temperature (°C)

  TE  -  External Temperature (°C)

1.6  REMOTE CONTROLS AND 

ROOM CHRONO-THERMOSTATS 

(OPTIONAL).

The boiler is prepared for the application of room 

chrono-thermostats or remote controls, which 

are available as optional kits. (Fig. 1-6)

All Immergas chrono-thermostats are connected 

with 2 wires only. Carefully read the user and 

assembly instructions contained in the accessory 

kit.

•  On/Off digital chrono-thermostat. The chrono-

thermostat allows:

  - to set two room temperature values: one for 

day (comfort temperature) and one for night 

(lower temperature);

  - to set up to four on/off differential weekly 

programs;

  - selecting the required function mode from 

the various possible alternatives:

  • permanent operation in comfort temp;
  • permanent operation in lower temp;
  •  permanent operation in adjustable anti-freeze 

temp.

  The chrono-thermostat is powered by two 1.5V 

LR 6 type alkaline batteries.

• Comando Amico Remoto Remote Control 

Device 

V2 

CAR

V2

) with climate chrono-

thermostat function. In addition to the 

functions described in the previous point, the 

CAR

V2

 panel enables the user to control all the 

important information regarding operation 

of the appliance and the heating system with 

the opportunity of easily intervening on the 

previously set parameters without having to 

go to the place where the appliance is installed. 

The Comando Amico Remoto 

V2

 Remote 

Control panel is provided with self-diagnosis 

to display any boiler operating anomalies. 

The climate chrono-thermostat incorporated 

into the remote panel enables the system flow 

temperature to be adjusted to the actual needs 

of the room being heated, in order to obtain 

the desired room temperature with extreme 

precision and therefore with evident saving 

in running costs. It also allows to display the 

effective room temperature and the external 

temperature (if external probe is present). 

The chrono-thermostat is fed directly by the 

boiler by means of the same 2 wires used for 

the transmission of data between boiler and 

chrono-thermostat.

Important:

 if the system is divided into zones 

using the relevant kit. the CAR 

V2

 must be used 

with its climate thermostat function disabled, i.e. 

it must be set to On/Off mode.

CAR

V2

 or chrono-thermostat On/Off electric 

connection (Optional).

 

The operations described 

below must be performed after having removed 

the voltage from the appliance.

 The eventual 

On/Off environment chrono-thermostat must 

be connected to clamps 40 and 41 eliminating 

jumper X40 (Fig. 3-2). Make sure that the On/

Off thermostat contact is of the “clean” type, 

i.e. independent of the mains supply, otherwise 

the P.C.B. would be damaged. Any CAR

V2

 must 

be connected by means of ter and - to 

clamps 41 and 44 on the P.C.B. (in boiler), 

eliminating jumper X40 and respecting polarity 

(Fig. 3-2). Connection with the wrong polarity 

prevents functioning, but without damaging the 

CAR

V2

 The boiler can only be connected to one 

remote control.

Important:

 If the CAR

V2

 remote control is used, 

arrange two separate lines in compliance with 

current regulations regarding electrical systems. 

No boiler pipes must ever be used to earth 

the electric system or telephone lines. Ensure 

elimination of this risk before making the boiler 

electrical connections.

Installation with system operating at direct 

low temperature.

 The boiler can directly feed a 

low temperature system by acting on parameters 

“S5” and S6” (par. 3.8). In this situation it is good 

practice to insert a relevant safety kit (optional) 

made up from a thermostat (with adjustable 

temperature). The thermostat must be positioned 

on the system flow pipe.

1.7  EXTERNAL PROBE (OPTIONAL).

The boiler is prepared for the application of the 

external probe (Fig. 1-7), which is available as an 

optional kit. Refer to the relative instruction sheet 

for positioning of the external probe.

The probe can be connected directly to the 

boiler electrical system and allows the max. 

system flow temperature to be automatically 

decreased when the external temperature 

increases, in order to adjust the heat supplied to 

the system according to the change in external 

temperature. The external probe always operates 

when connected, regardless of the presence or 

type of room chrono-thermostat used and can 

work in combination with Immergas chrono-

thermostats. The correlation between system 

flow temperature and external temperature is 

determined by the position of the central heating 

selector switch on the boiler control panel (or 

on the CAR

V2

 control panel if connected to the 

boiler) according to the curves shown in the 

diagram (Fig. 1-8). The electric connection of 

the external probe must be made on clamps 38 

and 39 on the terminal board positioned under 

the sealed chamber (Fig. 3-2).

Summary of Contents for VICTRIX X12-242I

Page 1: ...VICTRIX X 12 24 2 I IE Instruction and Warning book 1 036643ENG...

Page 2: ......

Page 3: ...user also in the case of transfer or succession of ownership It must be stored with care and consulted carefully as all of the warnings provide important safety indications for installation use and m...

Page 4: ...ation pump 19 1 25 Kits available on request 20 1 26 Boiler components 21 2 Instructions for use and maintenance 22 2 1 Cleaning and maintenance 22 2 2 General warnings 22 2 3 Control panel 22 2 4 Usi...

Page 5: ...pliance off immediately and contact a qualified technician e g the Immergas Technical Assistance centre which has specifically trained staff and original spare parts Do not attempt to modify or repair...

Page 6: ...by introducing a top quality anti freeze liquid into this circuit which is not noxious to health The instructions of the manufacturer of this liquid must be followed scrupulously regarding the percent...

Page 7: ...ional way using the couplings on the boiler template The boiler safety valve outlet must be connected toadrainingfunnel Otherwise themanufacturer declines any responsibility in case of flooding if the...

Page 8: ...i e it must be set to On Off mode CARV2 or chrono thermostat On Off electric connection Optional The operations described below must be performed after having removed the voltage from the appliance T...

Page 9: ...l Kit This information allows calculations to be made to verify the possibility of setting up various flue configurations Positioning of the gaskets black for green range flue extraction systems Posit...

Page 10: ...Intake and Exhaust 16 3 m 2 5 Intake m 18 7 Exhaust m 4 9 m 7 7 Exhaust m 13 6 Concentric vertical intake exhaust terminal 60 100 Intake and Exhaust 9 m 1 4 Intake m 10 3 Exhaust m 2 7 m 4 3 Exhaust...

Page 11: ...of the straps present in the kit making sure to block the 4 gasket flaps Fit the male side smooth of the exhaust terminal into the the female side of the bend 90 80 making sure that the relevant wall...

Page 12: ...o the external atmosphere The technical regulations in force must be respected Max length of exhaust duct The flue pipe vertical or horizontal can be extended to a max length of 30 straight metres Spa...

Page 13: ...al intake exhaust kit 80 125 Kit assembly Fig 1 18 for the installation of kit 80 125 the flanged adapter kit must be used to be able to install the flue system 80 125 Install the flanged adapter 2 on...

Page 14: ...l 6 and insert the intake exhaust pipe 5 Fit the 60 100 3 concentric terminal pipe with the male end 5 smooth into the flange 2 up to the stop making sure that the wall sealing plate has been fitted 3...

Page 15: ...sent in the lateral hole with respect to the central one according to needs and replace it with the flange 3 positioning the gasket 2 already present in the boiler and tighten using the supplied self...

Page 16: ...emoval of possible condensate forming in the exhaust pipe tilt the pipes towards the boiler with a min slope of 1 5 Assemble the lid A complete with adapter 1 and wall plugs 6 and assemble the flue to...

Page 17: ...e inside the flue technical slot The max possible length of the 60 flexible ducting vertical section is equal to 30 m This length is obtained considering the complete 80 exhaust terminal 1m of 80 pipe...

Page 18: ...nt the circulation pump by loosening the front cap and keeping the motor running Re tighten the cap after the operation 1 21 FILLING THE CONDENSATE TRAP On first lighting of the boiler combustion prod...

Page 19: ...24 CIRCULATION PUMP The Victrix X 12 24 2I series boilers are supplied with a built in circulation pump with 3 position electric speed control The boiler does not operate correctly with the circulatio...

Page 20: ...rmation of lime scale and preserves the original heat exchange and domestic hot water production conditions The boiler is prepared for application of the polyphosphate dispenser kit Relay board on req...

Page 21: ...ondensation module 11 Flue probe 12 Heat exchanger safety thermofuse 13 Manual air vent valve 14 Sample points air A flue gases F 15 Negative signal pressure point 16 Positive signal pressure point 17...

Page 22: ...ic hot water temperature selector switch 6 Central heating water temperature selector switch 7 Boiler manometer 8 DHW production phase functioning active 9 Boiler in block does not require release via...

Page 23: ...ite flame block 20 Return probe anomaly 23 Push button control panel anomaly 24 Block due to flue gas temperature gradient intervention 25 Insufficient circulation 27 Flue probe anomaly 29 Loss of rem...

Page 24: ...signal loss error occurs 6 times consecutively in 8 5 minutes 38 To eliminate the block the Reset button 3 must be pressed If this phenomenon occurs frequently contact a qualified technician for assis...

Page 25: ...TI FREEZE PROTECTION The boiler has an anti freeze function that switches on automatically when the temperature fallsbelow 4 C standardprotectiontominimum temperature of 5 C All information relative t...

Page 26: ...the gas flow rate regulation devices if settings are modified checktheproductionofDHW whentheboiler is connected to an external cylinder unit ensure sealing efficiency of water circuits check ventilat...

Page 27: ...ed for software updating operations 3 3 TROUBLESHOOTING N B maintenance interventions must be carried out by a qualified technician e g Immergas After Sales Technical Assistance Service Smell of gas C...

Page 28: ...eating output ignition power 3 6 ADJUSTMENT OF THE AIR GAS RATIO Important theverificationoperationsoftheCO2 must be carried out with the casing mounted while the gas valve calibration operations must...

Page 29: ...heating demand of the house Therefore the boiler works normally in a variable gas pressure field between minimum and maximum power depending on the system heat load setting fan speed in rpm hundreds...

Page 30: ...ich can be configured 0 Off 1 General alarm 2 CH phase active 3 External gas valve power supply 4 Secondary zone control from TA on relay board contact 5 Heat pump 0 5 0 P5 Relay 3 optional The boiler...

Page 31: ...every new power supply of the boiler by pressing buttons at the same time 2 and 4 Fig 2 1 for 5 seconds with boiler in stand by N B if the boiler is connected to the CARV2 the stand by function is onl...

Page 32: ...osen the two screws 4 present in the lower part of the casing front 3 unhook the central fixing 6 exerting slight pressure in the median zone of the side 5 pull the front casing slightly in the lower...

Page 33: ...sure of 1013 mbar Burner pressure values refer to use of gas at 15 C Victrix X 12 2 I Victrix X 24 2 I METHANE G20 BUTANE G30 PROPANE G31 HEAT OUTPUT HEAT OUTPUT BURNER GAS FLOW RATE BURNER NOZZLES PR...

Page 34: ...at Nom Q Min mg kWh 48 13 185 20 85 25 Flue temperature at nominal output C 56 63 57 Flue temperature at minimum output C 58 64 59 Victrix X 24 2 I Gas nozzle diameter 8205 gas valve mm 5 80 4 10 4 1...

Page 35: ...Nom Min 106 9 102 4 106 7 103 0 Efficiency 40 30 Nom Min 107 0 106 8 108 1 107 1 Heat loss at casing with burner On Off 80 60 C 0 89 0 30 0 41 0 50 Heat loss at flue with burner On Off 80 60 C 0 02 2...

Page 36: ...erial Number CHK Check Cod PIN PIN code Type Type of installation ref CEN TR 1749 Qnw min Minimum heating capacity domestic Qn min Minimum heating capacity heating Qnw max Maximum heating capacity dom...

Page 37: ......

Page 38: ......

Page 39: ......

Page 40: ...mergas com Immergas S p A 42041 Brescello RE Italy T 39 0522 689011 F 39 0522 680617 This instruction booklet is made of ecological paper Cod 1 036643ENG rev ST 000346 000 02 2014 Inglese per IRLANDA...

Reviews: