39
INS
TALLER
US
ER
MAINTEN
AN
CE TECHNI
CI
AN
3.22 VARIABLE HEAT OUTPUT.
N.B.:
the power data in the table has been ob-
tained with intake-exhaust pipe measuring 0.5
m in length. Gas flow rates refer to net heating
value below a temperature of 15°C and at a pres-
sure of 1013 mbar.
Victrix Maior 28 TT 1 ErP.
METHANE (G20)
PROPANE (G31)
THERMAL
POWER
THERMAL
POWER
MODULATION
BURNER GAS
FLOW RATE
BURNER GAS
FLOW RATE
(kW)
(kcal/h)
(%)
(m
3
/h)
(kg/h)
28.0
24080
D.H.W.
99
3.08
2.26
27.0
23220
96
2.97
2.18
26.0
22360
93
2.86
2.10
25.0
21500
89
2.74
2.01
24.0
20640
CEN.
HEAT.
+
D.H.W.
86
2.63
1.93
23.0
19780
82
2.52
1.85
22.0
18920
79
2.41
1.77
21.0
18060
75
2.29
1.68
20.0
17200
71
2.18
1.60
19.0
16340
68
2.07
1.52
18.0
15480
64
1.96
1.44
17.0
14620
60
1.85
1.36
16.0
13760
56
1.74
1.28
15.0
12900
52
1.63
1.20
14.0
12040
48
1.52
1.12
13.0
11180
44
1.41
1.04
12.0
10320
40
1.31
0.96
11.0
9460
36
1.20
0.88
10.0
8600
32
1.09
0.80
9.0
7740
28
0.98
0.72
8.0
6880
24
0.87
0.64
7.0
6020
19
0.76
0.56
6.0
5160
15
0.65
0.48
5.0
4300
10
0.54
0.40
4.0
3440
6
0.44
0.32
3.0
2580
4
0.33
0.24
2.8
2408
1
0.30
0.22
Victrix Maior 35 TT 1 ErP.
METHANE (G20)
PROPANE (G31)
THERMAL
POWER
THERMAL
POWER
MODULATION
BURNER GAS
FLOW RATE
BURNER GAS
FLOW RATE
(kW)
(kcal/h)
(%)
(m
3
/h)
(kg/h)
34.2
29412
99
3.70
2.71
33.5
28810
97
3.62
2.66
32.5
27950
94
3.51
2.58
31.5
27090
91
3.40
2.50
30.5
26230
88
3.29
2.42
29.5
25370
85
3.19
2.34
28.5
24510
82
3.08
2.26
27.5
23650
79
2.97
2.18
26.5
22790
76
2.86
2.10
25.5
21930
73
2.75
2.02
24.5
21070
69
2.65
1.94
23.5
20210
66
2.54
1.86
22.5
19350
63
2.43
1.78
21.5
18490
60
2.32
1.70
20.5
17630
57
2.22
1.63
19.5
16770
54
2.11
1.55
18.5
15910
50
2.00
1.47
17.5
15050
47
1.89
1.39
16.5
14190
44
1.79
1.31
15.5
13330
41
1.68
1.23
14.5
12470
37
1.57
1.15
13.5
11610
34
1.46
1.07
12.5
10750
31
1.36
1.00
11.5
9890
28
1.25
0.92
10.5
9030
24
1.14
0.84
9.5
8170
21
1.03
0.76
8.5
7310
18
0.92
0.68
7.5
6450
14
0.82
0.60
6.5
5590
11
0.71
0.52
5.5
4730
7
0.60
0.44
4.5
3870
4
0.49
0.36
3.5
3010
1
0.38
0.28