Parameter
Parameter
Description
Range
Default
t0
Central heating set
point minimum
temperature
Defines the minimum flow temperature.
20
÷
50 °C
25
t1
Central heating set
point maximum
temperature
Defines the maximum flow temperature.
(t0
+
5)
÷
85 °C
85
t2
DHW thermostat
Establishes the ignition and switch-off method of the boiler in DHW phase
(when the boiler is
connected to an external storage tank unit).
0 - Ignition occurs when the water contained in the storage tank drops by 3°C with respect to the
temperature set and switches off when the temperature is at the value set (solar activated)
1 - Ignition occurs when the water contained in the storage tank drops by 2°C with respect to the
temperature set and switches off when the temperature is at
+
1°C with respect to the value set
(solar deactivated)
2 - Ignition occurs when the water contained in the storage tank drops by 10°C with respect to
the temperature set and switches off when the temperature is at the value set (solar activated)
3 - Ignition occurs when the water contained in the storage tank drops by 5°C with respect to the
temperature set and switches off when the temperature is at the value set (solar activated)
0
On = -3°C
Off =
+
0°C
1
On = -2°C
Off =
+
1°C
2
On = -10°C
Off =
+
0°C
3
On = -5°C
Off =
+
0°C
2
t3
Solar delay timing
This function does not affect the correct functioning of this boiler model.
0 - 30 seconds
0
t4
Domestic hot water
priority timing
This function does not affect the correct functioning of this boiler model.
0 - 100 seconds
(step 10 sec)
2
t5
Central heating
ignitions timer
The boiler has electronic timing, which prevents the burner from igniting too often in central
heating mode
0 - 600 seconds
(step 10 sec)
18
t6
Central heating
ramp timer
In the heating stage, the boiler performs an ignition ramp in order to reach the maximum output set
0 - 840
seconds
(step 10 sec)
18
t7
CH ignition delay
from TA and CR
request
The boiler is set to switch-on immediately after a request. In the event of particular systems (e.g.
area systems with motorised thermostatic valves etc.) it may be necessary to delay ignition
0 - 600 seconds
(step 10 sec)
0
t8
Display lighting
Establishes the display lighting mode.
0 Automatic:
the display lights up during use and dims after 15 seconds of inactivity. In the event
of an anomaly the display flashes.
1 Low:
the display is always lit with low intensity
2 High:
the display is always lit with high intensity.
0 - 2
0
t9
Display
Establishes what the indicator displays 14 (Fig. 2-1).
"Summer" mode:
0: the indicator is always off
1: circulator active, it displays the flow temperature
pump off the indicator is off
"Winter" mode:
0: it always displays the value set on the central heating selector
1: circulator active, it displays the flow temperature
pump off always displays the value set on the CH selector
0 - 1
1
Id
Parameter
Parameter
Description
Range
Default
A0
Hydraulic model Defines the type of hydraulics in the boiler
Set
2
2
A1
-
Not used on this boiler model
-
-
A2
Model
Pump
Defines the type of circulator in the boiler
Set
0
0
A3
-
Not used on this boiler model
-
-
A4
-
Not used on this boiler model
-
-
A5
-
Not used on this boiler model
-
-
Id
Parameter
Parameter
Description
Range
Default
F0
Equivalent length
flue
Defines the length of the flue (see par. 3.10)
0 - 2
0
F1
-
Not used on this boiler model
-
-
In the event of an alteration, anomaly “E72” appears and fast calibration is required.