13
C32
C32
C32
C32
1-16
1-18
1-17
1-15
1
2
3
6
4
7
5
1
2
3
6
8
4
7
5
MAKS 45%
INS
TALLER
US
ER
MAINTEN
AN
CE TECHNI
CI
AN
The fixing plate kit includes:
N° 1 - Gasket (1)
N° 1 - Female concentric flange (2)
The Kit includes:
N° 1 - Int./exhaust concentric pipe Ø
60/100 (3)
N° 1 - Ring (4)
N° 1 - Aluminium tile (5)
N° 1 - Fixed half-shell (6)
N° 1 - Mobile half-shell (7)
The kit includes:
N° 1 - Gasket (1)
N° 1 - Female concentric flange (2)
N° 1 - Adaptor Ø 80/125 (3)
N° 1 - Int./exhaust concentric pipe
Ø 80/125 (4)
N° 1 - Ring (5)
N° 1 - Aluminium tile (6)
N° 1 - Fixed half-shell (7)
N° 1 - Mobile half-shell (8)
1.10 CONCENTRIC VERTICAL KIT
INSTALLATION.
Type C configuration, sealed chamber and
fan assisted.
Concentric vertical intake and exhaust kit. This
vertical terminal is connected directly to the out-
side of the building for air intake and flue exhaust.
N.B.:
the vertical kit with aluminium tile enables
installation on terraces and roofs with a maxi-
mum slope of 45% (approx. 25°) and the height
between the terminal cap and half-shell (374
mm) must always be observed.
Vertical kit with aluminium tile Ø 60/100.
To use this kit one must use the fixing plate kit
60/100 (sold separately).
Kit assembly (Fig. 1-15): install the concentric
flange (2) on the central hole of the boiler
inserting the gasket (1) and tighten using the
screws in the kit. Fit the male end (smooth)
of the adapter (3) into the female end of the
concentric flange (2). Imitation aluminium tile
installation. Replace the tile with the aluminium
sheet (5), shaping it to ensure that rainwater runs
off. Position the fixed half-shell (7) and insert
the intake-exhaust pipe (6). Fit the Ø 80/125
concentric terminal pipe with the male end (6)
(smooth) to the female end of the adapter (3)
(with lip gasket) up to the end stop; making sure
that the wall sealing plate (4) has been fitted, this
will ensure sealing and joining of the elements
making up the kit.
•Extensions for vertical kit Ø 60/100 (Fig. 1-16).
The kit with this configuration can be extended
to
a max. straight vertical length of 4.7 m
,
including the terminal. This configuration
corresponds to a resistance factor of 100. In
this case specific extensions must be requested.
Vertical kit with aluminium tile Ø 80/125.
Kit assembly (Fig. 1-17): to install the kit Ø
80/125 one must use the flanged adapter kit in
order to install the flue system Ø 80/125. Install
the flanged adaptor (2) on the central hole of the
boiler, positioning gasket (1) with the circular
projections downwards in contact with the boiler
flange and tighten using the screws contained
in the kit. Installation of the fake aluminium
tile: replace the tiles with the aluminium sheet
(4), shaping it to ensure that rainwater runs off.
Position the fixed half-shell (5) on the aluminium
tile and insert the intake-exhaust pipe (7). Fit the
Ø 80/125 concentric terminal pipe with the male
side (smooth) to the female side of the adapter (1)
(with lip gaskets) up to the end stop; making sure
that the wall sealing plate (3) has been fitted, this
will ensure sealing and joining of the elements
making up the kit.
• Extensions for vertical kit Ø 80/125 (Fig. 1-18).
The kit with this configuration can be extended
up to a
max. length of 12.2 m
including the ter-
minal. If additional components are assembled,
the length equivalent to the maximum allowed
must be subtracted. In this case specific exten-
sions must be requested.
MAXIMU
M
LEN
GTH
MAXIMU
M
LEN
GTH