1-28
21 - IE
INS
TALLER
US
ER
MAINTEN
AN
CE TECHNI
CI
AN
1.25 BOILER COMPONENTS.
Key:
1 - System filling valve
2 - Condensate drain trap
3 - Gas valve
4 - Domestic hot water probe
5 - Domestic hot water flow rate adjuster
6 - Safety thermostat
7 - Gas nozzle
8 - Delivery probe
9 - Venturi
10 - Detection electrode
11 - System expansion vessel
12 - Air intake pipe
13 - Condensation module
14 - Manual air vent valve
15 - Negative signal pressure point
16 - Positive signal pressure point
17 - Sample points (air A) - (flue gas F)
18 - Flue safety thermostat
19 - Heat exchanger safety thermal fuse
20 - System vent tank air valve
21 - System vent tank
22 - Ignition electrodes
23 - Fan
24 - Igniter
25 - Burner
26 - Return probe
27 - System pressure switch
28 - Vent valve
29 - System probe
30 - Boiler circulator pump
31 - system circulator pump
32 - DHW heat exchanger
33 - 3-way valve (motorised)
34 - 3 bar safety valve
35 - System draining valve
36 - hydraulic manifold