USE AND MAINTENANCE
INSTRUCTIONS
2.1 CLEANING AND MAINTENANCE.
Attention:
the heating systems must undergo
periodical maintenance (regarding this, see
the section dedicated to the maintenance
engineer, relating to “yearly appliance check
and maintenance”) and regular energy efficiency
checks in compliance with national, regional or
local provisions in force.
This ensures that the optimal safety, performance
and operation characteristics of the boiler remain
unchanged over time.
We recommend stipulating a yearly cleaning and
maintenance contract with your zone technician.
2.2 GENERAL WARNINGS.
Never expose the wall-mounted boiler to direct
vapours from a cooking surface.
Use of the boiler by unskilled persons or children
is strictly prohibited.
For safety purposes, check that the concentric
air intake/flue exhaust terminal (if fitted), is
not blocked.
If temporary shutdown of the boiler is required,
proceed as follows:
a) drain the heating system if anti-freeze is not
used;
b) shut-off all electrical, water and gas supplies.
In the case of work or maintenance to structures
located in the vicinity of ducting or devices
for flue extraction and relative accessories,
switch off the appliance and on completion of
operations ensure that a qualified technician
checks efficiency of the ducting or other devices.
Never clean the appliance or connected parts
with easily flammable substances.
Never leave containers or flammable substances
in the same environment as the appliance.
•
Attenzione:
the use of components involving
use of electrical power requires some
fundamental rules to be observed:
- do not touch the appliance with wet or
moist parts of the body; do not touch when
barefoot;
- never pull electrical cables or leave the
appliance exposed to weathering (rain,
sunlight, etc.);
- the appliance power cable must not be
replaced by the user;
- in the event of damage to the cable, switch
off the appliance and contact exclusively
qualified staff for replacement;
- if the appliance is not to be used for a certain
period, disconnect the main power switch.
N.B.:
the temperatures indicated by the display
have a tolerance of +/- 3°C due to environmental
conditions that cannot be attributed to the boiler.
Key:
- Stand-by - On Button
A
- Summer
( )
and winter
( )
operating mode button
B
- Not used on this model
C
- Reset
(RESET)
/ exit menu
(ESC)
button
D
- Menu entry button (
MENU
)/ data confirmation
(OK)
button
1 - Domestic hot water temperature selector
2 - Domestic hot water temperature set
3 - Central heating temperature selector
4 - Central heating temperature set
4 - Presence of anomalies
6 - Display of boiler functioning status
8 - Flame presence symbol and relative power scale
9 and 7 - Primary heat exchanger outlet water temperature
10 - Boiler in stand-by
11 - Boiler connected to remote control (Optional)
12 - Functioning in summer mode
13 - Anti-freeze function in progress
14 - Functioning in winter mode
15 - Not used on this model
16 - Connection to external tools for technician
17 - Display of menu items
18 - Functioning with external temperature probe active
19 - Display of data confirmation or menu access
20 and 7 - Outside temperature display
with external probe connected (optional)
21 - Display of reset or exit menu request
22 - Chimney sweep function in progress
23 - Boiler manometer
24 - Multi-function display
25 - Functioning in winter mode
26 - Heat pump operation in progress
2.3 CONTROL PANEL.