Technical documentation
Technical documentation
STESP ed 02/02
14
EOLO SUPERIOR PLUS
ELECTRICAL CIRCUIT
CAR
Remote control
CZ
Control xone unitt
DL1
Central heating operation LED
DL2
D.h.w. operation LED
DL3
Flame LED
E1/E2 Ignition electrodes
E3
Detection electrode
F
Fuse
IG
Main switch
MOD Modulation coil
MP
Circulator
MV
Fan
NB
D.h.w. NTC sensor
NE
External sensor
(optional)
NR
Central heating NTC sensor
P1
Room thermostat bridge
PU1
Reset button
SP
Pump pressure switch
SV
Flue pressure switch
TA
Room thermostat
TS
Overheat. safety thermostat
UB
Storage tank unit
VD
Electric three-way valve
V/G
Gas valve
The electric circuit is interlocked with a microprocessor electronic board that controls boiler functions.
The control and safety devices work in part at mains voltage and in part at low voltage.
230 V AC CIRCUIT
SAFETY DEVICES AND CONTROLS
Detection electrode (E3)
This detects ignition of the burner by whose flame it is invested.
It is connected to the detection circuit of the ignition unit.
Fuse
This interrupts power to the circuit when amp draw is over 3.15 A.
It is fitted on the modulation board.
Fuse
3.15 A 250 V
Depending on position, this allows:
Main switch
(IG)
0
-
circuit not powered
-
d.h.w. and CAR function
(optional)
-
d.h.w. and central heating function.
3-position switch
Overheat. safety device
(TS)
When the safety temperature (100 ºC) is exceeded, this interrupts power
to the main coils of the gas valve.
It is positioned on the flow pipe at the primary exchanger outlet.
Clicson double-
contact
thermostat