DIM A-2BT ERP Installation diagram (1 direct zone and 2
mixed zones).
Key:
S20-1 - Direct zone 1 room thermostat (RT)
S20-2 - Mixed zone 2 room thermostat (RT)
S20-3 - Mixed zone 3 room thermostat (RT)
1 - External probe (optional)
2 - Boiler
3 - Comando Amico Remoto
V2
remote control (optional)
RZ1 - Direct zone 1 return
RZ2 - Mixed zone 2 return
RZ3 - Mixed zone 3 return
MZ2 - Mixed zone 2 flow
MZ3 - Mixed zone 3 flow
MZ1 - Direct zone 1 flow
Factory settings define zone 2 as the main zone.
(See Fig. 20 for electrical connection and Fig. 21 for zones control unit
setting)
1.7 COMMISSIONING THE DEVICE.
System filling.
Once the device is connected, fill the system via
the boiler filling valve.
Filling is performed at low speed to ensure the release of air bub-
bles in the water via the boiler and central heating system vents
and the distribution manifold (if any).
Close radiator vent valves when only water escapes from them.
Close the filling cock when the boiler pressure gauge indicates
approx. 1.2 bar.
IMPORTANT:
during these operations, start the circulation
pumps by acting on the main switch positioned on the boiler
control panel after having activated the T.A. devices relating to
the various zones.
(Only for DIM H-LT and H-2LT ERP).
Act manually on the 3-way mixing vale using the relevant lever
on the electric actuator, keeping the same opening in order to
de-aerate the system and, if necessary, control the correct oper-
ating pressure.
Once these operations are complete, make sure that the lever on
the electric actuator is free from the manual lock position.
1.8 CIRCULATION PUMP.
The pump is ideal for the requirements of each central heating
system in a domestic and residential environment. In fact, the
pump is equipped with electronic control that allows you to set
advanced functions.
Adjustments.
Turn the selector and position it on the desired
curve to adjust the circulator pump.
Program
LED
P 1 lower (ΔP-V)
P 2 upper (ΔP-V)
green
C 3 lower (ΔP-C) - H=3 m
C 4 upper (ΔP-C) - H=4 m
orange
Min. - Max.
blue
-
Program P (1 lower 2 upper ) (ΔP-V) - Proportional curve
(green LED).
This allows the pressure level (head) to be pro-
portionally reduced as the system heat demand decreases (flow
rate reduction). Thanks to this function, the electric power con-
sumption of the circulator pump is reduced further: the energy
(power) used by the pump decreases according to the pressure
level and flow rate. With this setting, the pump guarantees
optimal performance in most heating systems, thereby being
particularly suitable in single-pipe and two-pipe installations.
Any noise originating from the water flow in the pipes, valves and
radiators is eliminated by reducing the head. Optimal conditions
for thermal comfort and acoustic well-being.
- Programs C (3 lower 4 upper ) (ΔP-C) - Constant curve (or-
ange LED).
The circulator pump maintains the pressure level
(head) constant as the system heat demand decreases (flow rate
reduction). With these settings, the circulator pump is suitable
for all floor systems where all the circuits must be balanced for
the same drop in head.