Immergas 3.030072 Instructions And Warnings Download Page 4

HYDRAULIC CONNECTION.

It is mandatory to install a 

safety device, set to be trig-

gered at 0.7 MPa (7 bars) 

(not supplied with the water 

heater), sized 3/4”, compliant 

with standard EN1487 as 

amended and added, and in 

any case compliant with local 

regulations in force: this safety 

device is to be fitted to the cold 

water inlet of the water heater 

and must be protected against 

freezing.

The safety unit must be fitted 

with a discharge device (over-

pressure) to be operated regu-

larly to remove any limestone 

deposits.

It must also be checked regu-

larly to ensure it is not blocked.

The pressure reducer (not 

supplied as standard) is re-

quired when the water mains 

pressure exceeds 0.5 MPa  

(5 bars) and must be mounted 

on the main water supply line.

The safety unit must also be 

connected to an open drain 

pipe, in a frost-free envi-

ronment, with a permanent 

downward gradient, to re-

move any expansion water 

from the heating process, or 

drainage water from the water 

heater.

The maximum operating 

pressure of the heat exchang-

er circuit must not exceed 

0.3 MPa (3 bars) and its max 

temperature must not exceed 

85°C.

To perform any discharge 

operations of the water heater, 

strictly adhere to the following 

sequence:

- disconnect the appliance 

from the electrical power 

supply.

- Disconnect the appliance 

from the mains water supply 

(cold water).

- Open the hot water tap.

- Actuate the discharge device 

of the safety unit.

WIRING.

Before removing the cover 

of the water heater, always 

ensure the power is discon-

nected, to prevent any risk of 

injury due to electric shocks.

The following must be provid-

ed upstream of the electrical 

system:
- a circuit breaker or 16A 

multi-pole fuse with contacts 

compliant with regulations 

in force.

- A 30 mA differential circuit 

breaker.

Should the power cable be 

found to be damaged for any 

reason, it must be replaced by 

the After-sales Support, and/

or in any case by skilled and 

qualified staff.

The water heater must be 

connected to earth according 

to the methods set out by the 

regulations in force.

A special terminal, suitably 

marked   is provided for the 

specific purpose.

This manual is supplied jointly 

with the water heater; in the 

event of loss it may also be 

obtained from the Authorised 

area Support service or be 

downloaded from the suitable 

website.

Summary of Contents for 3.030072

Page 1: ...RAPAX 200 V3 RAPAX 200 SOL V3 RAPAX 300 V3 RAPAX 300 SOL V3 IE Instructions and warnings Installer User Maintenance technician 1 043869ENG 1 043869ENG...

Page 2: ...alve 7 Fan 8 Compressor 9 User terminal board 10 Immersion heater 11 Domestic hot water sensor 12 High pressure sensor 13 Compressor protection thermostat 14 Compressor engage condenser Colour code ke...

Page 3: ...ed by excessive pressure due to the safety valve blocking because of ice Ensuretheflooronwhichthe appliance is to be installed is suitable to withstand the appliance s own weight and that of the water...

Page 4: ...exceed 0 3 MPa 3 bars and its max temperature must not exceed 85 C To perform any discharge operations of the water heater strictlyadheretothefollowing sequence disconnect the appliance from the elect...

Page 5: ...ntenance must be performed in compliance with the regulations in force according to the manufacturer s instructions and by professionally qualified staff intended as staff with specific technical skil...

Page 6: ...d components 8 2 Installation 10 2 1 Choosing the place of installation 10 2 2 Product installation 13 2 3 Hydraulic connection 13 2 4 Air intake connection 14 2 5 Electrical connection 14 2 6 Electri...

Page 7: ...ified staff only POSITIONS ALLOWED DURING TRANSPORT POSITIONS NOT ALLOWED DURING TRANSPORT Technical characteristics Unit of measurement Rapax 200 V3 Rapax 200 SOL V3 Rapax 300 V3 Rapax 300 SOL V3 Dim...

Page 8: ...urn to solar panels Rapax Sol V3 model only SC Condensate drain 20 RC 3 4 M Recirculation Rapax Sol V3 model only Ref Description Rapax 200 V3 Rapax 200 Sol V3 Rapax 300 V3 Rapax 300 Sol V3 A Condensa...

Page 9: ...piral unit 9 Fan 10 Spiral elastic 11 Terminal board unit Not shown manual dielectric connection con densate draining pipe safety unit 12 Front cover 13 Compressor 14 Compressor coating 15 Compressor...

Page 10: ...ferably insulated from the home s heated rooms Recommended room underground or base ment room where the temperature is higher than 10 C all year round garage boiler room with the exception of rooms wh...

Page 11: ...and recovery of waste calories from washing machines and tumble dryers Room in basement recovery of free calories released by the floor and walls of the base ment 2nd configuration installation in a h...

Page 12: ...y harmful for the duration in service of your water heater Connection to an attic In the presence of inadequate insulation between the building and the relative attics this type of installation may in...

Page 13: ...th a permanent downward gradient to remove any expansion water generated by the heating process or drainage water coming from the water heater itself The pipes used must withstand a temperature of 85...

Page 14: ...ductors with 2 5 mm section Installation shall consist of a circuit breaker or 16A multi pole fuse with contacts compliant with regulations in force A 30 mA differential circuit breaker If the power c...

Page 15: ...15 2 11 2 12 The ducts must be fitted to the adjustable air intake and outlet vents Specific cable duct...

Page 16: ...B B2 DHW probe K1 Domestic hot water unabling relay R1 Resistance 2 2 K Key A3 Integrated P C B B2 DHW probe N B With this configuration the boiler can show an error on the domestic probe Power suppl...

Page 17: ...e screen Follow the on screen instructions carefully to set parameters date and time air ducts language recirculation photovoltaic operating time slots anti legionella system After setting the paramet...

Page 18: ...1 Flat solar collectors 2 Electronic control unit 3 solar unit single circulation 4 Expansion vessel 5 Safety valve 6 System probe and venting unit 7 Mixing valve 8 Rapax Sol V3 Water heater 9 Non ret...

Page 19: ...sumes operation with the initial settings The BOOST can be interrupted at any time Pause the BOOST OPERATING mode Choose the operating mode Select AUTO or MANUAL see paragraph 3 6 Operating modes ABSE...

Page 20: ...ate or not the electrical integration support If it is off the device will never use the electrical integration in case of low temperatures a shortage of hot water is possible 3 6 SELECTING THE OPERAT...

Page 21: ...temperature in the tank Our product permanently calculates depending on the air temperature and the water temperature which energy is cheaper This SMART Energy function can decide to start heating wi...

Page 22: ...ing Fill the water heater by leaving a hot water tap open if the water flows it indicates that the water heater is full Check the water tightness of the seal and only then replace the thermostat and i...

Page 23: ...or out of measurement range from 20 to 110 PDC stoppage Central heating C H in ELEC Check the connections reference A4 and the correct application of the probe on the pipe Check the fan operation and...

Page 24: ...aporator works on the fan works on the compressor etc N B it is essential to disconnect the power cable on the terminal board so that the rear cover of the heat pump can be removed Fig 4 2 Remove the...

Page 25: ...an the filter see maintenance chapter Encrusted water heater Descale the water heater Continued water leak to the level of the safety unit outside the heating period Safety valve damaged or clogged Re...

Page 26: ...f calibration etc Insulating sheath cast iron steel or insulat ing missing on hot water connection pipes which could cause their corrosion Faulty electrical connection incorrect earth ing inadequate c...

Page 27: ...ditions 116 Energy efficiency in colder climate conditions 96 Energy efficiency in warmer climate conditions 130 Annual energy consumption in average climate conditions 883 kW h Annual energy consumpt...

Page 28: ...iency in colder climate conditions 100 Energy efficiency in warmer climate conditions 141 Annual energy consumption in average climate conditions 1334 kW h Annual energy consumption in colder climate...

Page 29: ...al energy efficiency after installation since such efficiency is affected by additional factors such as the heat loss in the distribution system and the size of the products compared to the size and f...

Page 30: ...38 40 39 50 55 60 65 75 80 85 100 115 123 131 130 150 160 170 163 188 200 213 M L XL XXL 3 2 3 2 The energy efficiency of the set of products indicated in this sheet may not reflect the actual energy...

Page 31: ...31...

Page 32: ...llo RE Italy Tel 0522 689011 Fax 0522 680617 Certified company ISO 9001 This instruction booklet is made of ecological paper This instruction booklet is made of ecological paper Cod 1 043869ENG rev ST...

Reviews: