5.4 Full On function
While the button FULL ON (7) is kept pressed, all stro-
boscopes will flash rapidly at the same time.
6
Specifications
Power supply: . . . . . . . 9 V /500 mA min. via
plug-in power supply unit
supplied that is connected
to 230 V~/50 Hz/18 V
Connections:
DMX control: . . . . . . 3-pole XLR jack
analog control: . . . . . four 2-pole 6.3 mm jacks,
control v5 V
power supply: . . . . . low voltage jack for a plug
with the dimensions
5.5/2.1 mm (outside/inside
diameter), positive pole at
the inner contact
Ambient temperature: . 0 – 40 °C
Dimensions: . . . . . . . . . 205 × 85 × 135 mm
6.1 Chase programmes (flash patterns) for the
stroboscopes 1 – 4
9
GB
All rights reserved by MONACOR
®
INTERNATIONAL GmbH & Co. KG. No part of this instruction manual may
be reproduced in any form or by any means for any commercial use.
Programme 0
random flash pattern
Programme 1
1234 full on
Programme 2
1-2-3-4 — 4-3-2-1
Programme 3
1-2-3-4-3-2-1
Programme 4
12-34 — 24-13— 23-14
Programme 5
1-12-123-1234-123-12-1-stop — 4-43-432-4321-432-43-4-stop
Programme 6
1-12-123-1234-234-34-4-stop — 4-43-432-4321-321-21-1-stop
Programme 7
1-3-2-4-3-1-4-2
Programme 8
12-23-34-41— 43-32-21-14
Programme 9
1 2-1 2 3-1 2-1 2 3 4
Subject to technical modification.