![Imesa D2W18 Instructions For Installation, Use And Maintenance Manual Download Page 12](http://html1.mh-extra.com/html/imesa/d2w18/d2w18_instructions-for-installation-use-and-maintenance-manual_2046343012.webp)
E190601X rev.6_ENG
May 30, 2022
12
For the connection use a cable of type H05 VV
–
F or higher sized as reported in the license plate data and in
the following tables. Interpose upstream of the appliance an omni polar disconnection device, i.e., capable of
disconnecting all the poles that make up the power supply of the machinery. A differential circuit breaker with
opening between the contacts is recommended, which allows complete disconnection under the conditions of
surge category III and complies with current regulations.
Make sure that the main switch of the machine is in the "0" position.
Open the inlet door for the power supply.
Pass the appropriately dimensioned power cable (see no table and below) through the cable press supplied
with the machine.
The electrical power cables must be connected to the on-board disconnector.
Depending on the type of power supply provided by the serial number plate of the machine, connect the wires
to the disconnector contacts marked as follows:
: terminal for the equipotential connection with the grounding system of the user.
L1, L2, L3: phase terminals
N: neutral terminal
When installing or replacing the power cord, the ground conductor must be at least 5 cm longer than the others.
ATTENTION!
The appliance must be connected to an effective ground system: the manufacturer declines all responsibility if
this connection is not carried out according to the provisions of the regulations in force on the subject.
If the washing machine is installed on a metal surface, suchand suchand ontheground and must be connected
to the ground system with a conductor independent ofthe grounding of the washing machine.
ATTENTION!
For tilting machines make sure that the movement of the machine does not compromise the connection to the
power supply panels.
ATTENTION!
For machines equipped with a servo-ventilated motor, make sure that the direction of rotation of the fan agrees
with the direction printed on the motor label. If it should be inconsistent, reverse the order of connection of the
phases directly from the main terminal board of the machine.