![Imer Group 1106007 Operating, Maintenance, Spare Parts Manual Download Page 30](http://html1.mh-extra.com/html/imer-group/1106007/1106007_operating-maintenance-spare-parts-manual_2046286030.webp)
30
IMER INTERNATIONAL S.p.A.
KOINE 3
INCONVENIENTI
CAUSE
RIMEDI
Machine does not start
Water
Water pressure too low: the gauge shows pressure below 2 bar
(green lamp on?), the display shows the text H
2
O
- Check that water is delivered from the supply
hose
- Check that the water filter is clean
- Check that the water pump is switched on
- If the pump collects from a tank, check that it has
been primed and there are
no leaks from couplings
Machine does not start
Material
-
Product too dry in mixing chamber
(mortar pump seized? red lamp on?)
- Initial start-up not performed correctly (see
para.11)
- Water flow rate setting too low (see para.11)
- No water delivered to mixing chamber
(water inlet obstructed, water solenoid valve
malfunction)
Machine does not start
Grid
-Grid not inserted completely, the display shows the text Bloc
-Check that the grid is positioned correctly
Machine does not start
Air
-
The air pressure, with jet valve completely open, does not fall
below the minimum pressure value on the machine pressure switch
(table 1)
- Check that the air hose is not bent or obstructe-
do
- Check that the jet nozzle is perfectly clean
Machine does not start
and compressor does
not start and the blue
light is OFF
Electrical current
-
No current delivered to connector of site panel
(fuses?)
- No power delivered to machine
(defective connector connection? loose cable?)
- Main switch not ON
- Check points listed alongside
Machine does not start
but compressor starts
Electrical current
- Start selector switch not in correct position
- Mixing chamber open
(start/stop pushbutton lamp on?)
- Mortar pump motor connector not inserted
(start/stop pushbutton lamp on?)
- Low water pressure switch trips on start-up
(water pump switched on
?see also "machine does not start due to
water)
- Check points listed alongside
Machine does not stop
and/or compressor
does not stop
Air
-
Air hose defective
(hose cut? Air leaks from couplings?
- Compressor air supply low
- Jet air valve faulty (blocked in open position)
- Check the air hose and couplings in particular
and replace if necessary
- Check air filter (see para. 12)
- Check compressor relief valve
Machine stops after
starting up
Water
-
Intake filter clogged
- Pressure reducer filter clogged
-
Water hose too long and/or too narrow
- Water supply insufficient
- Check points listed alongside: clean filters,
check for adequate flow rate from the water hose
(at least 10-12 l/min if working with lime-cement
based plaster, at least 15-20 l/min with gypsum
based plasters) and replace hose if necessary or
collect water from an auxiliary tank
Summary of Contents for 1106007
Page 7: ...7 IMER INTERNATIONAL S p A KOINE 3 11 13 12 14 1 5 4 6 10 2 3 8 7 9...
Page 13: ...13 IMER INTERNATIONAL S p A KOINE 3...
Page 17: ...17 IMER INTERNATIONAL S p A KOINE 3 11 13 12 14 1 5 4 6 10 2 3 8 7 9...
Page 23: ...23 IMER INTERNATIONAL S p A KOINE 3...
Page 27: ...27 IMER INTERNATIONAL S p A KOINE 3 11 13 12 14 1 5 4 6 10 2 3 8 7 9...
Page 33: ...33 IMER INTERNATIONAL S p A KOINE 3...
Page 37: ...37 IMER INTERNATIONAL S p A KOINE 3 11 13 12 14 1 5 4 6 10 2 3 8 7 9...
Page 43: ...43 IMER INTERNATIONAL S p A KOINE 3...
Page 47: ...47 IMER INTERNATIONAL S p A KOINE 3 11 13 12 14 1 5 4 6 10 2 3 8 7 9...
Page 53: ...53 IMER INTERNATIONAL S p A KOINE 3...
Page 54: ...54 IMER INTERNATIONAL S p A KOINE 3 Fig 1 Tav 1...
Page 57: ...57 IMER INTERNATIONAL S p A KOINE 3...
Page 60: ...60 IMER INTERNATIONAL S p A KOINE 3 Fig 4 Tav 4...
Page 61: ...61 IMER INTERNATIONAL S p A KOINE 3...
Page 64: ...64 IMER INTERNATIONAL S p A KOINE 3...
Page 68: ...68 IMER INTERNATIONAL S p A KOINE 3 SCHEMA ELETTRICO KOINE 3...
Page 69: ...69 IMER INTERNATIONAL S p A KOINE 3 SCHEMA ELETTRICO COMANDI KOINE 3...