MISTRAL M60, M90, M135 AND TC60 15
MAINTENANCE
Warning
Never service, repair or troubleshoot a unit unless you are a
professional air conditioning / refrigeration service person. Improper
servicing can lead to serious injury or death from fire, electric shock or
explosion.
TC60
Remove the front grille cover. Clean the compressor coil with a brush and
vacuum cleaner every three months or when dirty (whichever is sooner).
Replace the grille cover.
M60, M90, M90SD and M135
Every three months switch off the unit and remove the contents to gain access
to refrigeration service panel. Remove the service panel and insulation. Clean
the condenser coil and compressor with a brush and vacuum cleaner. Refit the
insulation and service panel. Restock the unit and switch on.
Other than regular cleaning the unit requires no maintenance by the end user. It
is recommended that the unit is serviced by an IMC approved engineer at least
once a year.
Details of IMC Service Contracts are available on application.
SERVICE PANEL