background image

Mistral M60, M90, M135

 

 

10 

 
 

CHANGING A LED LIGHT ASSEMBLY 

 
The cabinet interior is illuminated by a LED light strip fitting located at the front 
of the top inner panel.  
 
To change the light assembly: 

·

  Ensure the mains power to the unit has been turned off. 

·

  Open the front cabinet door(s). 

·

  Unscrew the screws holding the LED assembly in place. 

·

  Carefully lower the LED assembly down and disconnect the 2 wires from the 

unit. 

·

  The LED light assembly should now be free to fully remove from the unit. 

·

  To fit the replacement unit. 

·

  Place the new LED light assembly inside the unit, re connect the 2 wires 

from the unit to the new LED light assembly. 

·

  Re fit the LED light assembly inside the unit by using the screws. 

·

  Re-connect the mains power and ensure the light illuminates by means of 

the switch. 

 
 
 
 
 
 
 
 
 

Fixing  
Screws 

Fixing  
Screw

LED Light 
Assembly 
crews 

LED Light 
Assembly 
ews 

Summary of Contents for MISTRAL 13 Series

Page 1: ...0 and M135 Bottle Coolers Series 13 R290a Imperial Machine Company Limited Unit 1 Abbey Road Wrexham Industrial Estate Wrexham LL13 9RF Tel 44 0 1978 661155 Fax 44 0 1978 729990 Service Fax 44 0 1978...

Page 2: ...e protection requirements of the Electromagnetic Compatibility Directive 2014 30 EU and manufactured in accordance with harmonised standards EN 61000 6 1 2001 Immunity and EN 61000 6 3 2007 Emissions...

Page 3: ...N 11 COMMISSIONING 11 CHANGING THE CONTROLLER SET POINT 12 USING YOUR BOTTLE COOLER 12 CLEANING 13 CHANGING SHELF POSITION 13 MAINTENANCE 14 DO S AND DON TS 15 ORDERING SPARE PARTS 16 END OF LIFE DISP...

Page 4: ...tallations within the United Kingdom Export units carry 2 years parts only warranty Please observe these instructions carefully DELIVERY The packaged machine consists of M60 Bottle Cooler containing S...

Page 5: ...The following quantity of beverage bottles mixers can be held in each unit Bottle Cooler Capacity 330ml Bottles 150ml mixer cans M60 900h x 600w x 500d std M60 850h x 600w x 500d M60 800h x 600w x 500...

Page 6: ...35 6 Mistral Dimensions MODEL Y M60 STANDARD 900 M60 850 SHORT 850 M60 800 SHORT 800 M90 STANDARD 900 M90 850 SHORT 850 M90 800 SHORT 800 M135 STANDARD 900 M135 800 SHORT 800 500 mm Y mm 600mm 900mm 5...

Page 7: ...Mistral M60 M90 M135 7 500 mm Y mm 1350mm M135...

Page 8: ...d level floor Ensure a min 10mm clearance either side of the unit there is to be a min 20mm clearance at the top of the unit and a min 60mm clearance at the back The M135 is supplied on castors to aid...

Page 9: ...a LED light unit this light can be turned on or off by depressing the switch that is located on the underside of the worktop To access this switch the door must be opened the right hand furthest door...

Page 10: ...lace Carefully lower the LED assembly down and disconnect the 2 wires from the unit The LED light assembly should now be free to fully remove from the unit To fit the replacement unit Place the new LE...

Page 11: ...eplacement fuse cover has been obtained and fitted or the plug replaced WARNING This machine must be earthed Should the supply cord become damaged then a replacement must be fitted by an approved elec...

Page 12: ...stocked after closing at night or first thing in the morning to allow time for the bottles to cool Ensure that stock is rotated by placing new stock at the back of shelves or in one side of the cabine...

Page 13: ...ells CHANGING SHELF POSITION The shelves in all Mistral units are fully adjustable To adjust the shelves Remove the shelf Unclip the shelf supports as shown below Hook the shelf supports in the requir...

Page 14: ...d insulation block inside the cabinet after switching the unit off from the mains supply Clean the compressor coil with a brush and vacuum cleaner THIS MUST BE DONE every three months or when dirty wh...

Page 15: ...ace Do Ensure plug is accessible with the unit installed Do Regularly clean the condenser and compressor Do Rotate stock of bottles Don t Sit or stand on the unit worktop Don t Load with boxed goods D...

Page 16: ...ances The unit must be sent to a specialist recovery recycling and disposal site that is licensed for the disposal of refrigerated equipment Please note that the insulation in the Mistral range does n...

Page 17: ...Mistral M60 M90 M135 17 M60 WIRING DIAGRAM...

Page 18: ...Mistral M60 M90 M135 18 M90 WIRING DIAGRAM...

Page 19: ...Mistral M60 M90 M135 19 M135 WIRING DIAGRAM...

Page 20: ...Mistral M60 M90 M135 20 SPARES IDENTIFICATION FRONT Access Panel Electronic Controller Lock Shelf Clip Pilaster Strip Door Gasket Evaporator Fan Handle Shelf RH Door Glider Foot LH Door...

Page 21: ...Mistral M60 M90 M135 21 SPARES IDENTIFICATION REAR Compressor Refrigeration Pack Plastic Drip Tray Mains Cable...

Page 22: ...tronic Controller Red G42 020 Plastic Drip Tray G42 020 Plastic Drip Tray G60 348 M1 Mains Cable G60 348 M1 Mains Cable G60 349 Mains cable EU plug G60 349 Mains cable EU plug S76 300 Refrigeration Pa...

Page 23: ...keys E76 221 Access panel G30 561 Electronic Controller Red E77 123 Drip Tray 135 G60 348 M5 Mains Cable G60 349 Mains cable EU plug S76 302 Refrigeration Pack S76 308 Refrigeration Pack 220V 60Hz J0...

Page 24: ...Mistral M60 M90 M135 24 NOTES...

Page 25: ...Mistral M60 M90 M135 25...

Reviews: