background image

11

Table of Contents

About the McPC 10/100  . . . . . . . . . . . . . . . . . . . . . . . .1
Configuring the McPC 10/100  . . . . . . . . . . . . . . . . . . . .2
Modes of Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Auto-Negotiation and the McPC 10/100  . . . . . . . . . . . .4
Transparency  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Link Fault Detection  . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Installation  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Twisted Pair Crossover/Pass-Through Button  . . . . . . . . . .8
LED Indicators  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Technical Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
Specifications  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
Fiber Optic Cleaning Guidelines . . . . . . . . . . . . . . . . . . .10
Warranty  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
Federal Communications Commission 
Radio Frequency Interference Statement  . . . . . . . . . . . .12

At its option, IMC Networks will repair or replace at no charge the product

which proves to be defective within such warranty period.  This limited
warranty shall not apply if the IMC Networks product has been damaged by
unreasonable use, accident, negligence, service or modification by anyone
other than an authorized IMC Networks Service Technician or by any other
causes unrelated to defective materials or workmanship.  Any replaced or
repaired products or parts carry a ninety (90) day warranty or the remainder of
the initial warranty period, whichever is longer.

To receive in-warranty service, the defective product must be received at

IMC Networks no later than the end of the warranty period.  The product must
be accompanied by proof of purchase, satisfactory to IMC Networks, denoting
product serial number and purchase date, a written description of the defect
and a Return Merchandise Authorization (RMA) number issued by IMC
Networks.  No products will be accepted by IMC Networks which do not have
an RMA number.  For an RMA number, contact IMC Networks at PHONE:
(800) 624-1070 (in the U.S and Canada) or (949) 465-3000 or FAX: (949) 465-
3020.  The end-user shall return the defective product to IMC Networks,
freight, customs and handling charges prepaid.  End-user agrees to accept all
liability for loss of or damages to the returned product during shipment.  IMC
Networks shall repair or replace the returned product, at its option, and return
the repaired or new product to the end-user, freight prepaid, via method to be
determined by IMC Networks.

IMC Networks shall not be liable for any costs of procurement of substitute

goods, loss of profits, or any incidental, consequential, and/or special damages
of any kind resulting from a breach of any applicable express or implied
warranty, breach of any obligation arising from breach of warranty, or otherwise
with respect to the manufacture and sale of any IMC Networks product,
whether or not IMC Networks has been advised of the possibility of such loss
or damage.

EXCEPT FOR THE EXPRESS WARRANTY SET FORTH ABOVE, IMC

NETWORKS MAKES NO OTHER WARRANTIES, WHETHER EXPRESS OR
IMPLIED, WITH RESPECT TO THIS IMC NETWORKS PRODUCT, INCLUDING
WITHOUT LIMITATION ANY SOFTWARE ASSOCIATED OR INCLUDED.  IMC
NETWORKS SHALL DISREGARD AND NOT BE BOUND BY ANY
REPRESENTATIONS OR WARRANTIES MADE BY ANY OTHER PERSON,
INCLUDING EMPLOYEES, DISTRIBUTORS, RESELLERS OR DEALERS OF IMC
NETWORKS, WHICH ARE INCONSISTENT WITH THE WARRANTY SET
FORTH ABOVE.  ALL IMPLIED WARRANTIES INCLUDING THOSE OF
MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE
HEREBY LIMITED TO THE DURATION OF THE EXPRESS WARRANTY STATED
ABOVE.

Summary of Contents for McPC 10/100

Page 1: ...McPC 10 100 Operation Manual...

Page 2: ......

Page 3: ...rency 5 Link Fault Detection 6 Installation 7 Twisted Pair Crossover Pass Through Button 8 LED Indicators 8 Technical Support 9 Specifications 9 Fiber Optic Cleaning Guidelines 10 Warranty 10 Federal...

Page 4: ......

Page 5: ...below shows the DIP switch settings for McPC 10 100 FEATURE SWITCH FUNCTION DEFAULT LFD 5 Link Fault Detection Available in Force modes only OFF AN 6 Auto Negotiation Mode Valid only when Force mode...

Page 6: ......

Page 7: ...as switches hubs and repeaters all devices in the media conversion should ideally support and be utilizing Auto Negotiation functionality While it is possible to have auto negotiating devices on one s...

Page 8: ......

Page 9: ...rface to the McPC 10 100 is also down there is no output LFD causes the Link Up indicator of the link partner to blink When the McPC 10 100 is in one of the Force modes enable LFD by setting 5 to the...

Page 10: ......

Page 11: ...e twisted pair LNK link LED glow LED Indicators The McPC 10 100 features several diagnostic LEDs per port The LED functions are as follows T W I S T E D PA I R P O R T L Glows green when a twisted pai...

Page 12: ......

Page 13: ...r optic components are extremely susceptible to electrostatic discharge damage These components should only be handled directly by a qualified service technician using tools and techniques that confor...

Page 14: ......

Page 15: ...esigned to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy an...

Page 16: ......

Reviews: