• In 

Force 100 mode

, the McPC 10/100 acts as a 100Base-TX to

100Base-SX multi-mode or 100Base-FX single-mode fiber media
converter; 10 Mbps signals are not accepted.

To enable Force 100 mode, set switch 

7

to the 

ON

position, with

switches 

6

and 

8

in the 

OFF

position.

There is no auto-negotiation in either of the Force modes

Auto-Negotiation and the McPC 10/100 

When connecting two McPC 10/100s between two end stations (devices

such as switches, hubs and repeaters), all devices in the media conversion
should ideally support, and be utilizing, Auto Negotiation functionality.
While it is possible to have auto-negotiating devices on one side of the
media conversion and fixed (non-auto-negotiating) devices on the other,
link LEDs will react differently depending on where a link fault occurs.
Therefore, IMC recommends:

A)

Configuring every device in the media conversion for Auto-
Negotiation.

B)

For installations where Auto-Negotiation is NOT possible from one
end of the media conversion to the other, manually configure all
devices for 10 Mbps or 100 Mbps connections.

4

7

Installation

To install the McPC 10/100:

1. Power off the PC.

2. Remove the PC’s cover.

3. Find an empty ISA slot.

4. Align the McPC 10/100 in the slot.

5. Mount the McPC 10/100 by screwing its bracket to the computer

casing.

6. Make sure the McPC 10/100 does not extend past the edge of the

PC’s case.

7. Attach the keyed mini-power connector to the McPC 10/100.

8. Attach the male end of the “Y” connector to a standard size power

connector in the computer.

9. Replace the cover to the PC.

10.Attach the cables between the McPC 10/100 and the devices that

will be interconnected.

Summary of Contents for McPC 10/100

Page 1: ...McPC 10 100 Operation Manual...

Page 2: ......

Page 3: ...rency 5 Link Fault Detection 6 Installation 7 Twisted Pair Crossover Pass Through Button 8 LED Indicators 8 Technical Support 9 Specifications 9 Fiber Optic Cleaning Guidelines 10 Warranty 10 Federal...

Page 4: ......

Page 5: ...below shows the DIP switch settings for McPC 10 100 FEATURE SWITCH FUNCTION DEFAULT LFD 5 Link Fault Detection Available in Force modes only OFF AN 6 Auto Negotiation Mode Valid only when Force mode...

Page 6: ......

Page 7: ...as switches hubs and repeaters all devices in the media conversion should ideally support and be utilizing Auto Negotiation functionality While it is possible to have auto negotiating devices on one s...

Page 8: ......

Page 9: ...rface to the McPC 10 100 is also down there is no output LFD causes the Link Up indicator of the link partner to blink When the McPC 10 100 is in one of the Force modes enable LFD by setting 5 to the...

Page 10: ......

Page 11: ...e twisted pair LNK link LED glow LED Indicators The McPC 10 100 features several diagnostic LEDs per port The LED functions are as follows T W I S T E D PA I R P O R T L Glows green when a twisted pai...

Page 12: ......

Page 13: ...r optic components are extremely susceptible to electrostatic discharge damage These components should only be handled directly by a qualified service technician using tools and techniques that confor...

Page 14: ......

Page 15: ...esigned to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy an...

Page 16: ......

Reviews: