9
Troubleshooting
Issue - Compressor will not start
Possible
(1) Connect failure (2) Fuse broken or fuse burning
Resolution: (1) Make sure power converter is plugged into a functional electrical outlet and
make sure power converter is properly plugged into the compressor.
(1) Change the fuse.
Note: If using a 12V battery, make sure the jumper cables are properly connected
Issue - Compressor cannot reach high pressure air
Possible
(1) Air leaking (2) Seal balls problem
Resolution
– (1) Check all joints, connections, and screws to see if there is air leaking
(2) Change the seal balls inside
Issue
–
The air pressure rising slowly or can not reach
200Bar
Possible
(1) Air leaking (2) Second piston rings wear out (3) Check valve problem
Resolution
– (1) Check all joints, connections, and screws to see if there is air leaking
Summary of Contents for TXET062-1