background image

9

Troubleshooting

Issue - Compressor will not start

Possible

(1) Connect failure (2) Fuse broken or fuse burning

Resolution: (1) Make sure power converter is plugged into a functional electrical outlet and
make sure power converter is properly plugged into the compressor.
(1) Change the fuse.

Note: If using a 12V battery, make sure the jumper cables are properly connected

Issue - Compressor cannot reach high pressure air

Possible

(1) Air leaking (2) Seal balls problem

Resolution

– (1) Check all joints, connections, and screws to see if there is air leaking

(2) Change the seal balls inside

Issue

The air pressure rising slowly or can not reach

200Bar

Possible

(1) Air leaking (2) Second piston rings wear out (3) Check valve problem

Resolution

– (1) Check all joints, connections, and screws to see if there is air leaking

Summary of Contents for TXET062-1

Page 1: ...4500 PSI 300Bar Built in Conveter 12V Air Compressor Instruction Manual 12V compressor VI Series TXET062 1 Shutoff compressor manually TXET062 2 Shutoff compressor automatically Rev 1 1 2020...

Page 2: ...d reassembly will result in leaks damage and may void your warranty 6 Never attempt to dismantle any portion of this compressor when it is pressurized or is hot after running 7 This compressor is desi...

Page 3: ...3 Contents Specifications 4 Assembly Operation Instructions 5 6 TXET062 2 model function 7 Maintenance 8 Troubleshooting 9 10 After sales contact information 11...

Page 4: ...n transformer Size 33 26 5 33 5cm 13 10 43 13 19 inch Weight 9 5KG 20 9lb Working pressure 4500PSI 30Mpa 300Bar Cooling system Fan cooling Charging rate 20min 0 45L tank Motor power rating 250W OEM YE...

Page 5: ...re the smooth operation of the machine If 220V is required please purchase the corresponding model Important Make sure the converter is suiting your local power voltage 2 Tighten the screw below the c...

Page 6: ...DC power source Red connects to the positive terminal and black connects to the negative terminal When connected correctly the compressor fan will start automatically Otherwise the cooling fan will no...

Page 7: ...3 Picture D it shows when it reaches the pressure we set it can shutoff automatically IMPORTANT Don t set the output pressure above 4500PSI 300Bar 4 When running the compressor it shows the starting...

Page 8: ...nce it 1 Mainly clean these 4 connections it can reduce the chance of malfunctioning 2 Replace the filter cotton core inside we have put extra cotton fillers in our packing list 3 Drain the waste oil...

Page 9: ...a 12V battery make sure the jumper cables are properly connected Issue Compressor cannot reach high pressure air Possible 1 Air leaking 2 Seal balls problem Resolution 1 Check all joints connections...

Page 10: ...the corresponding check valve Issue Operating temperature too high Possible 1 long time use or bad ventilation 2 Fan rotary direction Resolution 1 No let the compressor continuously work cool the comp...

Page 11: ...questions please contact us to solve we will be happy to provide you with the best and highest quality service Thank you for your purchase Email support imaycc service com IMAYCC band make your outdoo...

Page 12: ......