7
TXET062-2 model function
Model number: TXET062-2 compressor
Setting Pressure Version
The compressor will auto when it reaches the pressure you set.
A
B
C
D
1= Fill Pressure Adjustment (Desired pressure pointer)
2=Starting pressure (Pressure pointer)
3= Adjustment Knob
Procedure
(1) Picture B, it tells us we using adjustment knob. This will engage the adjustment
and allow you to move the fill pressure adjustment pointer to the right. Set to
your desired max fill pressure.
(2) Picture C, the pointer stays status:
Starting pressure shows 0 (zero) condition
Desired Pressure pointer we set at 4500PSI
(3) Picture D, it shows when it reaches the pressure we set, it can shutoff
automatically.
IMPORTANT: Don’t set the output pressure above 4500PSI(300Bar)
(4) When running the compressor, it shows the starting pressure pointer reaching
the desired pressure pointer. That is the pressure we want.
(5) If you adjust the output pressure too high, you can bring it back down by simply
moving the adjustment knob to the left.
NOTE: DO NOT adjust the output pressure setting once the compressor is
running.
(6) When the compressor reaches the desired pressure we want (the intended
max fill pressure) it will shut off automatically.
(7) Be aware that the compressor switch will still be in the “ON “position after it
auto stops. You will need to turn it “OFF” before bleeding the pressure via the
pressure release valve.